Wipes DME 6 Chapter

When Brick (for two channels) is selected (pattern numbers 2801 to 2804, 2811 to 2814)

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Side V Size X

Horizontal magnification

0.01 to 8.00

 

 

 

 

2

Side V Size Y

Vertical magnification

0.01 to 8.00

 

 

 

 

3

Height

Height of brick

0.01 to 100.00

 

 

 

 

4

Center X

Horizontal center position

–100.00 to +100.00 a)

5

Center Y

Vertical center position

–100.00 to +100.00 b)

a)The horizontal center position of the video pasted on Side V. At –100.00 the center is at the left edge of the screen, and at +100.00 the center is at the right edge of the screen.

b)The vertical center position of the video pasted on Side V. At –100.00 the center is at the bottom edge of the screen, and at +100.00 the center is at the top edge of the screen.

When Frame in-out (for two channels) is selected

• Pattern numbers 2851 to 2854

Knob

Parameter

Adjustment

Setting values

 

 

 

 

5

Delay

Timing for video selected on

–100.00 to +100.00

 

 

a utility bus to appear on the

 

 

 

screen

 

 

 

 

 

• Pattern numbers 2861 to 2864

 

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Rot X

Rotation about the Y axis

–100.00 to +100.00

 

 

(horizontal direction)

 

 

 

 

 

2

Rot Y

Rotation about the X axis

–100.00 to +100.00

 

 

(vertical direction)

 

 

 

 

 

3

Rot Z

Rotation about the Z axis

–100.00 to +100.00

 

 

 

 

5

Delay

Timing for video selected on

–100.00 to +100.00

 

 

a utility bus to appear on the

 

 

 

screen

 

 

 

 

 

When Brick (for three channels) is selected (pattern number 3601)

Parameter group [1/2]

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Side V Size X

Side V horizontal

0.01 to 8.00

 

 

magnification

 

 

 

 

 

2

Side V Size Y

Side V vertical

0.01 to 8.00

 

 

magnification

 

 

 

 

 

3

Height

Height of brick

0.01 to 100.00 a)

4

Side V Center X

Side V horizontal center

–100.00 to +100.00 b)

 

 

position

 

 

 

 

 

468 Basic Procedure for DME Wipe Settings