5 Press [Set].

This assigns the signal.

Restrictions when using a dual link

When using a dual link, the switcher and DME resources are linked in duplex (link A and link B), resulting in the following restrictions.

Restrictions

Details

 

 

Functions that cannot be

Functions of the following items in the Engineering

used in the system

Setup >Switcher >Config menu

 

Single Simul, Dual Simul

 

 

 

Functions that cannot be

Primary inputs numbers 41 to 80

used in the switcher

Outputs number 25 to 48

 

Monitor buses 2/4/6/8

 

M/E-2 bank a)

 

M/E-3 bank

 

• DME utility 1 and 2 buses

 

• Color background 2 b)

 

Color corrector 2

 

Frame memory

 

Format converter

 

• Functions of the following items in the Engineering

 

 

Setup >Switcher >Config menu

 

 

Switching Timing, M/E Config excluding Standard, and

 

 

Logical M/E Assign

 

 

 

Functions that cannot be

DME channels 3, 4, 7, and 8

used on the DME

Freeze in film mode

 

• “Freeze Timing” in the following effects

 

 

Input Freeze, Trail, Decay, KF Strobe (always set to

 

 

Frame)

 

Brick

 

• Editor ports 3 and 4 when the editor port operation mode

 

 

is set to “Independent.”

 

 

 

Other restrictions

Auto chroma keying operates on the image of link A.

 

• Tallies are generated for the link A signal.

 

• Key frames are created in units of two frames.

 

• It is not possible to change the interpolation method in

 

 

the DME.

 

 

 

Functions 8000-MVS 1 Chapter

a)When the simple P/P software is not installed

b)When the switcher is a 2M/E system only

Dual Link Support 247