This saves the freeze image as a still image file in memory.

The destination folder is the folder selected in step 4 of “Combining the background image and input signal” (page 502).

If the entered folder name already exists, a message to confirm overwriting appears.

Selecting the way in which images are combined

To select the way in which the background image and input signal are combined (see page 90), use the following procedure.

1 In the <Type> group of the Still >Composite menu, select one of the following methods of combination.

Pattern Key: pattern key

Ext Key: external key

(This can only be selected when the pair mode is enabled. The signal selected on the frame memory source 2 bus is used as the key signal.)

Mix: mix

Nam: non-additive mix

If none of the above is selected, image combination is not carried out.

2 Depending on the selection in step 1, set the following parameters.

• When [Pattern Key] is selected

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Size

Size of pattern

0.00 to 100.00

 

 

 

 

2

Soft

Edge softness of pattern

0.00 to 100.00

 

 

 

 

3

Pattern

Pattern number

1 to 24 a)

a)The patterns are the same as for a standard wipe. See “Wipe Pattern List” in Appendix (Volume 1) (page 560).

• When [Ext Key] is selected

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Clip

Reference level for key

+109.59 to –7.31

 

 

signal generation

 

 

 

 

 

2

Gain

Key sensitivity

–100.00 to +100.00

 

 

 

 

• When [Mix] is selected

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Mix Rate

Mix proportion

0.00 to 100.00

 

 

 

 

Memory Frame 7 Chapter

Still Image Operations 505