Changing the key assignment for each output (Misc menu)

In Multi Program 2 mode you can change the key assignments independently. The following describes an example using M/E-1, but the operation is the same for other banks.

Notes

This setting is linked to the setting in the Engineering Setup >Switcher > Config >PGM Config menu.

It is not possible to make this setting while the above PGM Config menu is locked, or [Recall M/E Config] (see previous item) is set to Off.

1 In the M/E-1 menu, select first VF7 ‘Misc,’ then HF5 ‘Key Assign.’

The Key Assign menu appears, and the current key assignment is shown in the status area.

2 Change the setting in “Key Enable” as required.

Keys recalled in a snapshot recall

If a snapshot is recalled independently on main or sub, this only retrieves the settings for the key assigned to the recalled side. For example, if key 1 and key 2 are assigned on main, and key 3 and key 4 are assigned on sub, then if you recall a snapshot on main, this only retrieves the settings for key 1 and key 2, and the state of key 3 and key 4 assigned on sub is not affected.

Assigning sub preview output to preview selection buttons

You can assign the sub preview output to a preview selection button in the fade-to-black control block or downstream key/fade-to-black control block.

For details, see “Overall Control Panel Settings (Config Menu)” in Chapter 16 (Volume 2).

When the Multi Program 2 license is valid, by assigning the “Shift” function to a button, you can assign two preview outputs, “Shift” and “Unshift” to a single button. To use the shift output, always assign “Shift” to some button.

Changing the matrix size to Standard

When using a router, if the matrix size is set to [Compact (128×128)], it is not possible to control the utility 3 bus on the S-Bus. When using Multi Program 2, in the <Matrix Size> group of the Engineering Setup >Router/Tally >Router menu, select [Standard (136×138)].

For details, see “Assigning switcher inputs and outputs to S-Bus space” in Chapter 16 (Volume 2).

Functions 8000-MVS 1 Chapter

Multi Program 2 239