
Operating manual
15.4Save the CAN configuration for the start-up test.
Saving a CAN configuration to a file serves to check the CAN configuration is correct when starting the system up. The CAN configuration must only be saved to a file after having verified that it is correct.
Save the CAN configuration.
When the CAN bus level is selected, it shows the SAVE softkey that may be used to save the current CAN configuration. The configuration is saved in the file C:\Cnc8070 \mtb \data \canData.tab.
This file contains the number of groups present in the bus, the number of modules, the number of inputs and outputs, etc.
Verify the CAN configuration during power-up.
To verify the configuration, the information must be previously saved to the file canData.tab.
During the
"The CAN configuration is not the same as the one saved in the file"
Once the error is detected, it will keep coming up even after a reset. There two ways to correct the error:
•Power up the CNC again with the original CAN configuration; the one saved in the canData.tab file
•Save the new CAN configuration. The CAN configuration must only be saved to a file after having verified that it is correct.
15.
DIAGNOSIS | |
| Save the CAN configuration for the |
CNC 8070
(SOFT V03.0X)
321