‡‡ ‡ Operating manual

13.

ASSISTANCE

Oscilloscope

SETUP

 

CNC 8070

(SOFT V03.0X)

Variables that may be modified at the Sercos drive

Drive

Name

Update

 

 

 

CP1

CP1.axis

Immediate

 

 

 

CP2

CP2.axis

Immediate

 

 

 

CP3

CP3.axis

Immediate

 

 

 

CP30

CP30[set].axis

Immediate

 

 

 

CP31

CP31[set].axis

Immediate

 

 

 

CP32

CP32[set].axis

Immediate

 

 

 

NP1

NP1.axis

Immediate

 

 

 

RP1

RP1.axis

Immediate

 

 

 

RP2

RP2.axis

Immediate

 

 

 

RP3

RP3.axis

Immediate

 

 

 

RP4

RP4.axis

Immediate

 

 

 

RP51

RP51.axis

Immediate

 

 

 

RP52

RP52.axis

Immediate

 

 

 

RP53

RP53.axis

Immediate

 

 

 

RP54

RP54.axis

Immediate

 

 

 

SP1

SP1[set].axis

Immediate

 

 

 

SP2

SP2[set].axis

Immediate

 

 

 

SP50

SP50.axis

Immediate

 

 

 

SP51

SP51.axis

Immediate

 

 

 

TP10

TP10.axis

Immediate

 

 

 

TP11

TP11.axis

Immediate

 

 

 

TP12

TP12.axis

Immediate

 

 

 

TP13

TP13.axis

Immediate

 

 

 

TP14

TP14.axis

Immediate

 

 

 

Besides the parameters shown in the previous table, the user may access any variable having a writing permission if he knows its name. To do this, use the following nomenclature:

Indicate the axis, the name of the parameter and the set separated by a period.

When modifying any parameter of the previous table, the change is effective immediately without having to reset or restart the unit even when there is a program in execution.

The drive parameters modified with this method are functional immediately, but these values will be lost when the drive is turned off. Use the "Save to flash" option to maintain the modified values of those machine parameters.

278

Page 312
Image 312
Fagor America CNC8070 manual Variables that may be modified at the Sercos drive, RP4