Operating manual
13.
ASSISTANCE | Oscilloscope |
SETUP |
|
CNC 8070
(SOFT V03.0X)
Variables that may be modified at the Sercos drive
Drive | Name | Update |
|
|
|
CP1 | CP1.axis | Immediate |
|
|
|
CP2 | CP2.axis | Immediate |
|
|
|
CP3 | CP3.axis | Immediate |
|
|
|
CP30 | CP30[set].axis | Immediate |
|
|
|
CP31 | CP31[set].axis | Immediate |
|
|
|
CP32 | CP32[set].axis | Immediate |
|
|
|
NP1 | NP1.axis | Immediate |
|
|
|
RP1 | RP1.axis | Immediate |
|
|
|
RP2 | RP2.axis | Immediate |
|
|
|
RP3 | RP3.axis | Immediate |
|
|
|
RP4 | RP4.axis | Immediate |
|
|
|
RP51 | RP51.axis | Immediate |
|
|
|
RP52 | RP52.axis | Immediate |
|
|
|
RP53 | RP53.axis | Immediate |
|
|
|
RP54 | RP54.axis | Immediate |
|
|
|
SP1 | SP1[set].axis | Immediate |
|
|
|
SP2 | SP2[set].axis | Immediate |
|
|
|
SP50 | SP50.axis | Immediate |
|
|
|
SP51 | SP51.axis | Immediate |
|
|
|
TP10 | TP10.axis | Immediate |
|
|
|
TP11 | TP11.axis | Immediate |
|
|
|
TP12 | TP12.axis | Immediate |
|
|
|
TP13 | TP13.axis | Immediate |
|
|
|
TP14 | TP14.axis | Immediate |
|
|
|
Besides the parameters shown in the previous table, the user may access any variable having a writing permission if he knows its name. To do this, use the following nomenclature:
Indicate the axis, the name of the parameter and the set separated by a period.
When modifying any parameter of the previous table, the change is effective immediately without having to reset or restart the unit even when there is a program in execution.
The drive parameters modified with this method are functional immediately, but these values will be lost when the drive is turned off. Use the "Save to flash" option to maintain the modified values of those machine parameters.
278