‡‡ ‡ Operation manual

11.

PLC

service

 

"Logic analyzer"

8070 CNC

(SOFT V03.0X)

The value is given in milliseconds or microseconds according to the active units and the selected value will be displayed in the information area.

There is a mark that changes states every 2ms.

With a time base of 10ms, 20ms and 4ms it will look like this.

While the graphic window is selected, use the "+" and "-" keys to divide or multiply this time base by two.

Start distance / Trigger distance

This data is only shown when there is a trace.

Start distance

It represents the time difference between the indicator

 

cursor and the base point of the trace (beginning of the

 

trace if there is no trigger point or it has not been

 

reached).

Trigger distance

It represents the time difference between the indicator

 

cursor and the trigger point (if it has taken place).

The value is updated when moving the indicator cursor of the graphic area. Its value may also be edited, thus updating the cursor position in the graphic area.

Reference distance

This data is only shown when there is a trace already and the operator has put a reference signal. It represents the time difference between the indicator cursor and the reference signal.

The value is updated when moving the indicator cursor of the graphic area. Its value may also be edited, thus updating the cursor position in the graphic area.

Trace status

This element cannot be edited, it automatically reflects the status of the trace. The possible messages are:

Empty.

Beginning.

Executing.

Stopping.

Full.

236

Page 270