Fagor America CNC8070 manual Description of resource tables, Timers, Registers, Binary resources

Models: CNC8070

1 358
Download 358 pages 2.35 Kb
Page 275
Image 275

‡ ‡ ‡ Operation manual

11.10.1 Description of resource tables

As mentioned earlier, the user resources and symbols defined are displayed in different tables. Each table shows the following information.

Timers

This table shows the timers and user defined symbols for the timers and their status.

This table has the following fields:

GIt indicates whether any of the trigger inputs of the timer is active (TG1, TG2, TG3 or TG4).

M Timer status:

S - Stopped.

T - Timing.

D - Disabled.

EStatus of the Enable input (TEN).

R Status of the Reset input (TRS)

T Status output.

ET

Elapsed time.

TO

Remaining time.

The inputs and outputs that are high will be indicated with a green symbol.

Registers

This table shows the registers and user symbols defined for the registers as well as their values.

The values may be shown in decimal, hexadecimal or binary format.

Binary resources

This table shows the binary resources (inputs, outputs, messages, errors) and the user defined symbols for the binary resources as well as information on the their status.

Counters

This table shows the counters and user symbols defined for the counters as well as their status.

This table has the following fields:

EStatus of the enable input (CEN).

U Status of the Count-up input (CUP).

D Status of the Countdown input (CDW).

P Status of the preset input (CPR).

S Status output.

C Value of the internal count of the counter.

The inputs and outputs that are high will be indicated with a green symbol.

11.

PLC

service

 

"Monitoring"

8070 CNC

(SOFT V03.0X)

241

Page 275
Image 275
Fagor America CNC8070 manual Description of resource tables, Timers, Registers, Binary resources, Counters