‡‡ ‡ Operating manual

3.3.2Stop condition

3.

AUTOMATIC MODE

Data screen (softkeys)

CNC 8070

To set the block where the execution of the program or subroutine will be interrupted. After executing that block, the execution may be resumed with the [START] key or canceled with the [RESET] key.

If the last block is not set, the program execution will end executing one of the end- of-program functions "M02" or "M30".

When selecting this option, the softkey menu of the CNC shows the options available for selecting the stop condition. To return to the main menu, press the key for the previous menu.

Subroutine selection

To select the stop condition in a global subroutine which has been called upon from the program. When selecting this option, the CNC shows a list of programs available for selecting the desired subroutine.

Keys for selecting a program

To switch windows.

To move the cursor thru the elements of the window.

To open the selected subroutine.

To cancel the selection and close the program listing.

To select a subroutine from the list.

1.Select the folder containing the subroutine.

2.Select the program containing the subroutine or write its name in the bottom window.

3.Press [ENTER] to open the program or [ESC] to cancel the selection and close the program listing.

The program window will show the contents of the selected subroutine.

Last block

It sets as execution interrupting block the one currently selected with the cursor. If the last block is not set, the program execution will end executing one of the end-of- program functions "M02" or "M30".

The last block may be selected using the cursor or the "Find text" or "Go to line" options of the softkey menu.

Keys to move the cursor

Moves the cursor line by line.

To move the cursor page by page.

Moves the cursor to the first block or to the end of the program.

The set last block remains active until canceled (with [ESC] key) or until the program is executed; in that case, the execution will end in one of functions "M02" or "M30".