Operation manual
11.
PLC | service |
| "Monitoring" |
8070 CNC
(SOFT V03.0X)
11.10.2 Definition of the table resources
Each table shows the following resources and user symbols:
Timer table
•Timers (T1...T256).
•User symbols defined for the timers.
Counter table
•Counters (C1...C256).
•User symbols defined for the counters.
Register table
•Registers (R1...R1024).
•User symbols defined for the registers.
•
Binary resource table
•Inputs (I1...I1024) and outputs (O1...O1024).
•Marks (M1...M8192).
•Messages (MSG1...MSG256) and errors (ERR1...ERR256).
•User symbols defined for the binary resources.
•
When defining a resource or user symbol, it will be added to the corresponding table.
Data entry
The resources and user symbols of the tables are defined at the data entry area. Their values may be changed by directly assigning a value to them (M110=1, R300=34). If it is a hexadecimal value, it must be preceded by the "$" sign (M10=$1, R200=$20).
The window saves the last "N" assignments so they can be recalled later on. In order to make selecting easier, it is possible to display a window with the list of the assignments already made.
Keys for defining the data of the logic analyzer
To select the assignments.
To assume the selected assignments.
To show the list of the assignments made.
To close the list of the assignments made.
To remove a resource or user symbol from a table, select that element and press [SUP].
Keys for defining the data of the logic analyzer
To select one of the tables.
To moves the cursor element by element.
To move the cursor page by page in the table.
To move the cursor to the beginning or end of the table.
To delete the selected resource of the table.
242