Operating manual
Trigger data
In this area, the user may select the trigger conditions. The options offered by this trigger data area are:
Trigger
It indicates when the data capture begins.
If not selected, the data capture begins as soon as the user gives the command to begin. The "Flank", "Level" and "Position" data are ignored.
If selected, the trigger condition must be specified with the "Flank", "Level" and "Position" data.
Channel
It indicates which variable or channel (CH1, CH2, CH3, CH4) is to be used as reference or trigger condition.
Flank
It may be
It is taken into account when trigger has been selected.
Trigger level
It sets the value to be assumed by the variable to start capturing data.
It is taken into account when trigger has been selected.
Position (%)
It is taken into account when Trigger has been selected.
It is defined as a percentage, between 0% and 100%. It indicates the number of samples to be taken before the Trigger. For example, a 10% position indicates that 10% of the total number of programmed samples will be taken before the Trigger and the remaining 90% after that instant.
The Trigger condition is evaluated after gathering the indicated % of samples. If the position is defined as 50% and the Trigger condition takes place after taking 10% of the samples, it is ignored until capturing 50% of the samples.
Machine parameters to be set
In this area of the data window, it is possible to directly change the values of up to 20 machine parameters to be adjusted.