Wiring

Section 3-3

Remove the covers from the tips of the cables’ ST connectors if there are covers protecting the ST connectors.

Optical Connector Cover

Rotate the cover 90°

Pull off the cover.

counterclockwise.

 

Note To replace the Optical Connector Cover, just reverse the steps shown in the diagram above.

4.Turn the cable connector so that the tab in the connector faces left and aligns with the slot in the Unit’s connector. Insert the cable connector fully into the Unit’s optical connector. Press and turn the cable’s connector clockwise to lock the connector in place.

Unit's optical Cable

connector connector

Slot

Press and turn the metal fitting on

 

the cable connector until it locks.

Tab

 

Align the tab in the cable connector with

 

the slot in the Unit's connector and fully

 

insert the cable connector.

 

Note To remove the connector, just reverse the steps shown in the diagram above. (Press and turn the cable connector’s metal fitting counter- clockwise to unlock the connector.)

5.After installing the Optical Fiber Cable, fix the tension member of the Opti- cal Fiber Cable.

Insert the connectors completely and always check that the connectors are locked before starting operation.

When installing Optical Fiber Cables, be sure to stay within the specifications (e.g., tensile strength, bending, lateral pressure) for the cables used.

Optical Fiber Cables

Use Optical Fiber Cables (Graded Index: GI) with the following optical specifi- cations.

50/125 m AGF Cable

Item

Minimum

Standard

Maximum

Unit

 

 

Conditions

 

 

 

 

 

 

 

 

Numerical Aper-

---

0.21

---

 

---

Theoretical value

 

ture (N.A.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmission

---

---

3.0

Lf

dB

0.5 km

Lf

λ = 0.8 m

loss

 

 

 

 

 

 

 

Ta = 25°C

 

 

3.0

Lf + 0.2

 

0.2 km

Lf < 0.5 km

 

 

 

3.0

Lf + 0.4

 

Lf < 0.2 km

 

 

 

 

 

 

 

 

 

 

Connection loss

---

---

1.0

 

 

λ

= 0.8 m, one location

 

 

 

 

 

 

 

 

 

Transmission

500

---

---

 

MHzkm

λ

= 0.85 m (LD)

 

bandwidth

 

 

 

 

 

 

 

 

 

77