Memory AreasAppendix B

Parameters for Automatically Setting Data Links with Equality Layout: D30000 + 100 (Unit

No.) + 1 to 9 (See page 145.)

 

15

 

 

 

 

 

 

8

7

 

 

 

 

 

 

0

 

 

 

+1

Area 1 data link start word (BCD)

 

 

 

 

 

 

 

 

 

 

 

+2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Area 1 type

 

 

 

 

 

 

00

 

 

 

 

 

 

 

 

 

 

+3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of send words per node of area 1 (BCD)

 

 

 

 

 

 

 

+4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rightmost 4 digits of data link start word of area 2 (DM area) (BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

Leftmost digit of data link start word of area

 

 

 

+5

Area 2 type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 (BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+6

Number of send words per node of area 2 (BCD)

 

 

 

 

 

 

 

+7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

First data link status word (BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

14

13

12

11

10

9

8

7

 

6

5

4

3

2

1

0

 

 

Nodes to participate in the data links

+8

16

15

14

13

12

11

10

9

8

 

7

6

5

4

3

2

1

 

 

 

 

 

 

 

 

The numbers indicate node numbers.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+9

32

31

30

29

28

27

26

25

24

 

23

22

21

20

19

18

17

 

 

 

 

The value assigned indicates whether the

+10

48

47

46

45

44

43

42

41

40

 

39

38

37

36

35

34

33

 

 

node is to participate in the data links.

 

 

 

Participate:

1

+11

62

61

60

59

58

57

56

 

55

54

53

52

51

50

49

 

 

Not participate: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BCD: Set the value as binary-coded decimal.

Parameters for Automatic Data Link Creation with 1:N Allocation: D30000 + 100 (Unit No.) + 12 to 25

Common Type

 

15

 

 

 

 

 

 

 

 

8

7

 

 

 

 

 

 

 

 

 

0

N+12

 

 

 

 

1:N allocation type (Set value 0001 = Common type)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N+13

 

 

 

 

 

 

 

Start word for area 1 (bit-access area, BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N+14

 

 

 

Area for area 1

 

 

 

 

 

 

 

 

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N+15

 

 

 

 

 

Area 1 send size (number of words) for master node (BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N+16

 

 

 

 

 

Area 1 send size (number of words) for slave nodes (BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N+17

 

 

 

 

 

Rightmost 4 digits of start word of area 2 (DM area) (BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N+18

 

 

 

Area for area 2

 

 

 

 

Leftmost digit of start word of area 2 (BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N+19

 

 

 

 

 

Area 2 send size (number of words) for master node (BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N+20

 

 

 

 

 

Area 2 send size (number of words) for slave nodes (BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N+21

 

 

 

 

 

 

First word to store data link status (bit-access area) (BCD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N+22

16

15

14

13

 

12

 

11

10

9

8

 

7

6

5

 

4

3

2

 

1

N+23

32

31

30

29

 

28

 

27

26

25

24

 

23

22

21

 

20

19

18

 

17

N+24

48

47

46

45

 

44

 

43

42

41

40

 

39

38

37

 

36

35

34

 

33

N+25

---

---

62

61

 

60

 

59

58

57

56

 

55

54

53

 

52

51

50

 

49

Words N+22 through N+25 register nodes that will participate in the data links. The numbers shown in the table are the node addresses. The bit status for each node address indicates whether the node is to participate in the data links.

Participate: ON

Not participate: OFF

352

Page 375
Image 375
Omron C200HW-CLK21, CVM1-CLK21, CS1W-RPT01, CJ1W-CLK21-V1, CQM1H-CLK21, CS1W-CLK21-V1 Memory AreasAppendix B, Common Type