Omron CQM1H-CLK21, CVM1-CLK21, CS1W-RPT01, CJ1W-CLK21-V1, C200HW-CLK21, CS1W-CLK21-V1 359

Models: CS1W-RPT01 CJ1W-CLK21-V1 CVM1-CLK21 CQM1H-CLK21 CS1W-CLK21-V1 C200HW-CLK21

1 401
Download 401 pages 33.98 Kb
Page 382
Image 382

Memory Areas

Appendix B

Local Data Link Participation Status: CIO 1500 + 25 (Unit No.) + 6 (See page 304.)

1: Local node data link participating

0: Local node data link not participating or data link inactive

Data Link Status: CIO 1500 + 25 (Unit No.) + 7 to + 22 (See pages 156, 305.)

When the first data link status word for manually set data link tables or for automatically set data links is not set or is set to 0, the data link status is stored in the words shown below.

+7

Node

2

Node

1

+8

Node

4

Node

3

+9

Node

6

Node

5

+10

Node

8

Node

7

+11

Node

10

Node

9

+12

Node

12

Node

11

+13

Node

14

Node

13

+14

Node

16

Node

15

+15

Node

18

Node

17

+16

Node

20

Node

19

+17

Node

22

Node

21

+18

Node

24

Node

23

+19

Node

26

Node

25

+20

Node

28

Node

27

+21

Node

30

Node

29

+22

Node

32

Node

31

PLC status

0:Inactive (user program not running)

1:Active (user program running)

PLC's CPU Unit error

0:Normal

1:Error

Communications error (data link reception)

0:Normal

1:Error

Data link participation

0:Not in data link or data link inactive

1:In data link

 

 

 

Offset error

Error: Offset exceeds

 

 

 

 

 

 

0: Normal

number of send words.

 

 

 

1: Error

 

 

 

Insufficient (short) receive area Insufficient: Receive

 

 

 

0: Sufficient

area is smaller than

 

 

1: Insufficient

send area. Excess data

 

 

 

 

is truncated; other data

 

 

 

 

is received.

Remaining receive area

Remaining: Receive

0: Not remaining

area is larger than send

1: Remaining

area. Data is received

 

 

 

 

and remaining words

 

 

 

 

are cleared.

359

Page 382
Image 382
Omron CQM1H-CLK21, CVM1-CLK21, CS1W-RPT01, CJ1W-CLK21-V1, C200HW-CLK21, CS1W-CLK21-V1 operation manual 359