Omron CQM1H-CLK21, CVM1-CLK21, CS1W-RPT01, CJ1W-CLK21-V1, C200HW-CLK21 Using Fins Commands

Models: CS1W-RPT01 CJ1W-CLK21-V1 CVM1-CLK21 CQM1H-CLK21 CS1W-CLK21-V1 C200HW-CLK21

1 401
Download 401 pages 33.98 Kb
Page 178
Image 178

Starting and Stopping Data Links

Section 5-3

CVM1 and CV-series Start Bit

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Word N

N: DM 2000 + 100 (unit number)

CQM1H-series Start Bit

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

AR 07

Data link Start Bit

Start: Changed from OFF to ON or set to ON when power is turned on

Stop: Changed from ON to OFF

Data link Start Bit

Start: Changed from OFF to ON or set to ON when power is turned on

Stop: Changed from ON to OFF

5-3-2 Using the Controller Link Support Software and CX-Programmer

Data links can be started or stopped using commands on the Data Link Menu of the Controller Link Support Software. The node for which starting and stop- ping is being specified must participate in the data links.

Using a Programming Device Connected to PLC Node

IBM PC/AT or

Controller Link Support Software or

compatible

CX-Net (in CX-Programmer)

 

 

 

 

 

 

 

 

 

 

 

 

Node in data links

Start/stop data links

Note The Controller Link Support Software cannot be connected to a CS-series PLC.

Use the CX-Net (in CX-Programmer).

Using a Computer Node

Controller Link

IBM PC/AT orSupport Software compatible

Controller Link

Support Board

Start/stop data links

Node in data links

Data links can be started or stopped from the Controller Link Support Board on the local node.

5-3-3 Using FINS Commands

Data links can be started and stopped by sending the RUN and STOP FINS commands from a node on the Controller Link to a node that is in the data links.

Issuing the FINS Command from a Computer Node

IBM PC/AT or

compatibleFINS command:

RUN/STOP

Controller Link

Support Board

Node in data links