6. System Setup

ID Setup and Remote Enable

fa=pÉíìé=~åÇ=oÉãçíÉ=bå~ÄäÉ=

 

Encore system setup: Step 1.

1

In this procedure, you will set up individual Encore Video Processor IDs. If ScreenPRO-II,

PresentationPRO-II and/or ImagePRO units are used as destinations, you will also set their

IDs and enable remote control. Each unit in your system must have a unique ID. „ Use the following steps to set up IDs and remote control:

1. Power up your Encore Controller, and allow it to fully boot up. This is the system’s DHCP server.

2. To set Encore Video Processor IDs:

a. Using the Unit ID Selector on the rear of each Processor, set the desired ID. Logical IDs 1 - 16 are available.

b. If you elect to use “extended” IDs 17 - 32, use the Video Processors ID Definition Menu to redefine the IDs. In Chapter 5, refer to the “Video Processors ID Definition Menu” section on page 202 for details.

Important

If you are setting up a “stack” configuration, the ID of the bottom stack Video Processor must always be lower than the ID of the top stack Processor.

c.Repeat step 3 for all other Video Processors in your system.

3.Power up all Encore Video Processors, ScreenPRO-II units, PresentationPRO-II units and ImagePRO units in your system. This sequence enables the Encore Controller to “serve” IP addresses to the Processors and other peripherals.

4.To set ScreenPRO-II and PresentationPRO-II IDs and enable remote control:

a.Ensure that the ScreenPRO-II and PresentationPRO-II units are connected to the same Ethernet Switch as the Video Processor(s).

b.Press {REMOTE CONTROL} on the Home Menu to access the Remote Control Menu.

c.Scroll to the Unit ID line, and select a unique ID. The ID range is 1 to 32.

d.Scroll to the Remote Control/DHCP line, and enable remote control.

Note

When remote control is on, the {HOME} buttons disappears, the ScreenPRO-II (or PresentationPRO-II) front panel is disabled, and the unit’s IP address is dynamically assigned. All control now originates from Encore’s console.

e.Press {SAVE} to save the system state in non-volatile memory — so that it will return to it should power need to be cycled.

f.Repeat step 4 for all other ScreenPRO-II and PresentationPRO-II units in your system.

5.To set ImagePRO IDs and enable remote control:

a.Ensure that the ImagePRO units are connected to the same Ethernet Switch as the Video Processor(s).

262

 

Encore Presentation System • User’s Guide • Rev 04

 

Page 262
Image 262
Barco 26-0313000-00 manual Fa=pÉíìé=~åÇ=oÉãçíÉ=bå~ÄäÉ=, Encore system setup Step