5. Menu Orientation

System Menu

Press {NEXT IP QUAD} to advance to the next 3-digit set of numbers in the address. Use the ADJ knob in the normal manner to change the digits.

Press {TEST COMM} to test communications with the defined router:

~If the test is successful, a “ROUTER CONNECTED” message will appear that includes the Router name and version.

~If the test is unsuccessful, a “ROUTER FAILED” message will appear. In this condition, re-check all connections and settings, and repeat the test.

RS-232 Setup Menu

On the Router Specification Menu, when Communication Type is set to RS-232, press {COMM SETUP} to display the RS-232 Setup Menu:

 

RS232 SETUP

 

 

B

Baud Rate

115200

 

A

N

C

 

 

A

K

 

 

Data Bits

[ 8 ]

V

 

 

Parity

[ NONE ]

 

 

Stop Bits

[ 1 ]

 

 

 

 

A

 

 

 

D

 

 

 

J

 

TEST

 

 

 

COMM

 

 

Figure 5-38.RS-232 Setup Menu (sample)

 

 

The RS-232 Setup Menu enables you to set the router’s RS-232 baud rate only. All other parameters are fixed.

Baud Rate — sets the desired baud rate (9600, 14400, 19200, 28800, 38400, 57600, 115200).

Data Bits — fixed at 8.

Parity — fixed at None.

Stop Bits — fixed at 1.

Press {TEST COMM} to test communications with the defined router:

~If the test is successful, a “ROUTER CONNECTED” message will appear that includes the Router name and version.

~If the test is unsuccessful, a “ROUTER FAILED” message will appear. In this condition, re-check all connections and settings, and repeat the test.