68 Encore Presentation System • User’s Guide • Rev 04
3. Hardware Installation
Installation
qêáéäÉ=pÅêÉÉå=`çåÑáÖìê~íáçå

The figure below illustrates a block diagram of a triple screen Encore configuration. This

diagram can be used as reference in the procedure. Please note:

Aux destinations are not shown in the diagram below.
This procedure can be used for configurations consisting of from 2 to 32 screens.
A VP must be used for each single destination. VPx cannot be used.
Figure 3-2. Block Diagram, Triple Screen Encore Configuration

For this configuration, you will need:

PG 2
PVW
PG 1
Projector #1 Projector #2 Projector #3
Program #1 Program #2 Program #3
Preview #1 Preview #2 Preview #3
Controller SC or LC
VP #1
VP #2
VP #3
Ethernet Switch
PG 2
PVW
PG 1
PG 2
PVW
PG 1
Scaled
Sources
Unscaled
Sources
M/E Inputs
Scaled
Sources
Unscaled
Sources
Scaled
Sources
Unscaled
Sources
To:
Routers
ScreenPRO-II
PresentationPRO-II
ImagePRO
Table 3-3. Equipment List, Triple Screen Encore Configuration
Qty. Item Note
3 VP VPx cannot be used.
1 Controller Model LC or SC
3 Video Projectors Customer supplied.
6 DVI or Analog Monitors Program and Preview (customer supplied).
1 Ethernet Switch Customer supplied