3. Hardware Installation

Installation

c.To connect two (or more) serial routers, a third-party Ethernet-to-Serial converter is required, such as the Lantronix model UDS100, UDS200 or UDS2100 (http://www.lantronix.com). Each UDS2100 can control two serial routers.

Using RS-232 cables, connect each router to the UDS2100.

Set up a static IP address on the Lantronix. The recommended range is 192.168.0.191 - 192.168.0.240 — so as not to conflict with Encore devices. See the Lantronix User’s Guide.

Using an Ethernet cable, connect the UDS2100 to the same switch as the Controller and VPs.

d.Ensure that all sources are connected to your router(s).

e.Connect all selected router outputs to the desired M/E inputs.

9.ScreenPRO-II Connections — if your system includes one (or more) destination ScreenPRO-II units, you can configure them for internal or external routing:

a.When External routers are used, connect two outputs from an Analog router to any two HD-15 inputs on the ScreenPRO-II. An SDI router can also be connected to BNC inputs 1 and 2. During setup, these specific patches will be defined using the Output Patch Menu.

b.When Internal routing is used, connect Analog sources to inputs 1 - 8 on the HD-15 connectors, and SDI sources to BNC inputs 1 and 2. During setup, these patches will be defined using the Input Patch Menu.

In Chapter 6, refer to the ScreenPRO-II Destination Setup” section on page 279 for more information.

10.Output Connections

a.For each VP, connect the analog or digital Preview Output to the input of the associated Preview Monitor.

b.For each VP, connect the analog or digital Program 2 Output to the input of the associated Program Monitor.

c.For each VP, connect the analog or digital Program 1 Output to the input of the associated projector.

d.Connect the Program Out HD/SDI connector to an SDI or HDTV monitor as required, or to the proper video distribution equipment.

Note

This output only works if the selected output resolution is a valid SDI or HD/SDI format.

11.Aux Destinations — you can configure three types of Aux destinations: Aux (monitors), ImagePRO Aux and PresentationPRO-II Aux. Refer to Appendix D, Working With Destinations” on page 393 for interconnection details.

12.Power Connection — connect AC power cords to the AC Power Connectors on the rear of each VP and Controller, and then to AC outlets. Connect AC Power cords (or AC adapters) to all peripheral equipment. Please note:

~Connect each unit only to a properly rated supply circuit.

~Reliable grounding of rack-mounted equipment should be maintained.

13.Tally Connection — the Controller provides one 25-pin D connector for issuing tally “relay closure” commands to external devices. Eight circuits are provided. In Appendix A, refer to the “Tally Connector” section on page 374 for details.