bK==^ééäáÅ~íáçå=kçíÉë

Encore Controller to Router Connections

i~åíêçåáñ=bíÜÉêåÉí=íç=pÉêá~ä=`~ÄäÉ=`çååÉÅíáçå

Because Encore Controllers only have one RS-232 serial port (EXT COMM), an external device (such as the Lantronix UDS200 or UDS2100) is required for multiple RS-232 connections. The Lantronix UDS200 or UDS2100 connects to Encore via Ethernet, and provides two RS-232 ports.

The table below illustrates the pinouts on the UDS200's serial connector.

Note

Data "direction" information is provided from the point of view of the UDS200 or UDS2100.

5 1

9 6

Figure E-4.Ext Comm Connector

Encore Controller (SC or LC)

Lantronix

UDS200

Ethernet Switch

MatrixPRO SDI Router

MatrixPRO Analog Router

Figure E-5.Lantronix Configuration

Table E-4.Lantronix Connector Pinouts

Pin

Signal

Description

Note

1

CD

Carrier Detect

 

 

 

 

 

2

RXD

Received Data

Receives data. Connects to router's transmitting pin

 

 

 

 

3

TXD

Transmitted Data

Sends data. Connects to router's receiving pin.

 

 

 

 

4

DTR

Data Terminal Ready

 

 

 

 

 

5

GND

Signal Ground

Connects to Ground Pin on Router

 

 

 

 

6

DSR

Data Set Ready

 

 

 

 

 

7

RTS

Request To Send

 

 

 

 

 

8

CTS

Clear To Send

 

 

 

 

 

9

RI

Unused

 

 

 

 

 