Image 41

INSTALLATION

NAP-200-101

Sheet 1/3

Installation of ACD Agent Position

Figure 3-4shows the cable connection between the Agent Position and the NEAX2400 IMX.

 

MDF

PIM

Dterm No.0

 

(Dterm Series III/Series E)

 

Installation Cable

PA-16ELCJ

No.1

LT

 

 

No.15

Max. 850m (0.5φ )

MDF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.0

 

26

B0

1

A0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.1

 

 

27

B1

2

A1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.2

 

 

28

B2

3

A2

 

 

 

 

 

 

 

 

 

 

Note 1

 

 

 

 

 

No.3

 

 

29

B3

4

A3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.4

 

 

30

B4

5

A4

 

 

 

 

 

 

A0

 

 

 

 

 

 

 

 

B0

 

No.5

 

 

31

B5

6

A5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.6

 

 

32

B6

7

A6

 

Note 1:

Connector leads (A0 and B0)

 

 

 

 

 

 

 

 

 

 

 

 

No.7

33

B7

8

A7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

may be connected with Modu-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.8

34

B8

9

A8

 

 

 

1

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.9

 

 

35

B9

10

A9

 

 

lar Rosette.

3

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

No.10

36

B10

11

A10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.11

37

B11

12

A11

 

 

Modular Rosette

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.12

38

B12

13

A12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.13

39

B13

14

A13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.14

40

B14

15

A14

 

 

Modular Jack

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.15

41

B15

16

A15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43

 

18

 

 

 

 

 

 

 

 

 

Agent Position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4419

4520

4621

4722

4823

49

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

25

1

 

3

 

 

 

 

 

16ELC Camp

2

4

 

 

 

 

 

 

 

 

Connector Leads (example)

Note 2: For more details of connector lead accommodation, see “Circuit Card Manual”.

Figure 3-4 Connection of ACD Agent Position