NEC 2400IMX system manual SW10 For Port SW11 SW12 MIS Port Interface

Models: 2400IMX

1 485
Download 485 pages 63.2 Kb
Page 76
Image 76

PH-PC27 (EAPI)

SWITCH

NAME

SW10

(for Port 0)

SW11

(for Port 1)

SW12

(for Port 2)

MIS Port Interface

SWITCH NO.

 

 

SETTING

 

STANDARD

 

 

 

MEANING

 

 

 

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW01-1

 

SW01-2

 

 

SW01-3

 

NON-PROTOCOL RS-232C

 

 

 

 

 

SW11-1

 

SW11-2

 

 

SW11-3

 

PORT DATA SPEED SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

ON

 

 

ON

 

300 bps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

ON

 

ON

 

 

OFF

 

600 bps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

OFF

 

 

ON

 

1200 bps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

OFF

 

 

OFF

 

2400 bps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

ON

 

 

ON

 

4800 bps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

OFF

 

ON

 

 

OFF

 

9600 bps

 

 

 

 

 

OFF

 

OFF

 

 

ON

 

19200 bps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the non-protocol RS-232C port stop bit

 

 

 

ON

 

length to 1 bit.

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the non-protocol RS-232C port stop bit

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

length to 2 bit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the non-protocol RS-232C port data length

 

 

 

ON

 

to 7 bit.

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the non-protocol RS-232C port data length

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

to 8 bit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

SW01-6

 

SW01-7

 

 

NON-PROTOCOL RS-232C PORT

 

 

 

 

SW11-6

 

SW11-7

 

 

 

PARITY BIT SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

ON

 

ODD Parity Check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

OFF

 

EVEN Parity Check (standard setting)

 

7

 

 

 

 

 

 

 

 

 

 

OFF

 

OFF

 

No Parity Check is to be made

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the polarity of non-protocol RS-232C PB

 

 

 

ON

 

 

 

signal to Not Provided.

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the polarity of non-protocol RS-232C PB

 

 

 

 

 

 

 

 

 

 

OFF

 

signal to +, or sets PB signal to Provided.

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Ports 0, 1 and 2 translate to MIS ports 1, 2 and 3.

NDA-24282CHAPTER 4