NEC 2400IMX system manual NAP-215-108 Sheet 1/1 Emergency Recorder

Models: 2400IMX

1 485
Download 485 pages 63.2 Kb
Page 341
Image 341

ACD SERVICE FEATURES FUNCTIONAL TEST PROCEDURES

NAP-215-108

Sheet 1/1

Emergency Recorder

START

C.O. trunk call incoming.

Place a C.O. trunk call from station A to station B.

Supervisory position

Agent position

Recorder

Announcement

Trunk

 

 

ELC/DLC

 

COT

 

ELC/DLC

 

LC

A

 

B

 

 

LC

Incoming at ACD agent position.

Answering by ACD agent position.

Emergency recording operation.

• Press the EMER key on the agent position.

Incoming at supervisory position.

When the ACD calls is terminated at the supervisory position, the LCD on the supervisory position indicates the emergency recording request and the MON lamp also illuminates.

At the same time, the recorder starts recording.

In the period above, the agent position and C.O. trunk is in the communicating status.

Answering by supervisory position.

The supervisory position answers the call as an ACD call and monitors it (three-party conference call does not occur).

The agent position can confirm the answering of the supervisory position by the change of the lamp indication on the agent position (flashing steady) as well as from the LCD display.

Confirmation of recording.

• Check that the call is recorded by the recorder.

The supervisory position presses the MON key to start three-party conference call. Note

Release by ACD agent position.

When the agent position releases the incoming C.O. trunk call, it is transferred to the supervisory position.

Confirmation of communication.

Check that the supervisory position is communicating with the C.O. trunk. Release by supervisory position.

Apply the test procedure above to all splits.

END

Note: After MON key is pressed, “BARGE?” is displayed. At that time, monitoring is abandoned by one of the following operations.

Dial “1” + “#” (Three-party conference will be established.)

Press MON key again

CHAPTER 6

NDA-24282 (E)

Page 322

 

Revision 1.0

 

Page 341
Image 341