NEC 2400IMX system manual Amno Assignment of Monitored Number, Mno, Nmi, Ucd, Mfc

Models: 2400IMX

1 485
Download 485 pages 63.2 Kb
Page 373
Image 373

AMNO: Assignment of Monitored Number

AMNO: Assignment of Monitored Number

1.Function

AMNO is used to assign monitored numbers into the PBX database. The numbers programmed in AMNO will also be programmed into ACDPLT (the ACD database). The monitored numbers programmed in AMNO are the entry points for pilot numbers into the ACD system.

2.Precautions

1.When the monitored number (MNO) is deleted, delete MNO in ACDPLT prior to this command.

2.When UCD=1 is programmed in this command, UCD service should be programmed beforehand.

3.Parameters

TN:

Tenant Number of Monitored Number

MNO:

Monitored Number (maximum 5 digits. the number is the same as the pilot number

 

assigned in ACDPLT and must match the numbering plan of the NEAX2400 IMX.

NMI:

Number Monitored Index (1 ~ 4095)

UCD:

UCD degrade

 

0 – No

 

1 –Yes

STN:

UCD Control Station Number (Available for UCD=1) Note 1

A/G:

Station type of Hotel System Note 2

 

A: Administration Station

 

G: Guest Station

MFC:

G-2 Signal Data for MFC (0-3) Note 3

 

0 = ASFC, SFI 59 = 0 and SFI 60 = 0

 

1 = ASFC, SFI 59 = 1 and SFI 60 = 0

 

2 = ASFC, SFI 59 = 0 and SFI 60 = 1

 

3 = ASFC, SFI 59 = 1 and SFI 60 = 1

Note: Each monitored number must be assigned to different Monitored Number Index. “0”cannot be assigned at the first digit of the monitored number.

Note 1: When a C.O. trunk is used for UCD control station, UCD controlling station number should be programmed in ACSI in advance.

Note 2: For Business System, “A (Administration Station)” is assigned here.

Note 3: Valid for countries except Australia and North America.

CHAPTER 7

NDA-24282 (E)

Page 354

 

Revision 1.0

 

Page 373
Image 373
NEC 2400IMX system manual Amno Assignment of Monitored Number, Mno, Nmi, Ucd, Mfc