INFOLINK DATA MESSAGES - ACD

OPERATING PROCEDURE

Depending on the usage of each application.

SERVICE CONDITIONS

1.Each feature is defined by the detail specification of each application.

2.Lower layer protocol of Infolink supports TCP/IP + DIX Ethernet Version 2.

3.Infolink Data Messages are provided to the ACD tenant programmed in ACDTN.

4.Two-way communications link is provided simultaneously.

5.One link controls one ACD tenant.

6.OAI transmission is also provided via the same link.

7.An IVR equipment may be accommodated per ACD tenant.

PROGRAMMING

Step 1:

ASDT

 

 

TN:

Tenant number (1-10)

 

STN:

Station number of the IVR (maximum 5 digits)

 

TEC:

1-4

Step 2:

ASHU

 

 

Assign the UCD group organized by the station number accommodates the IVR port

Step 3:

ACDTN

 

 

IVR PILOT NUMBER : IVR Pilot number for UCD service programmed in ASHU

 

 

: Outbound Answer Timer (0-60 sec.)

Step 4:

ACDIVR - Assign the desired IVR port number for all station numbers to access IVR programmed

 

in ASDT

 

 

DIRECTORY NUMBER:IVR station number programmed in ASDT

 

PORT:

IVR port number (1-255)

Step 5:

ACDCCV - when IVR announcement service is provided. Note 1

 

ACTION: IVR ANNOUNCEMENT: Note 2

ARGUMENT: IVR announcement equipment number (1-99) Note 3

Announcement ID for announcement order via Infolink to the IVR

Note 1: When this command data has already been programmed for OAI features, it is not necessary to program the data again.

Note 2: It is not necessary to programa Pause step after the IVR Announcement.

Note 3: The announcement number varies depending on each IVR Specifications.

CHAPTER 5

NDA-24282 (E)

Page 256

 

Revision 1.0

 

Page 275
Image 275