ACNO: Assignment of Conversion Number Data

ACNO: Assignment of Conversion Number Data

1.Function

ACNO is used to direct a specified ringdown type trunk route to a specific monitored number (monitored number is the same as a pilot number).

Note: This command does not apply to self-directing type trunks (i.e. DID, TIE Lines, etc.).

2.Precautions

1.Prior to this command, program the monitored number by AMNO and ACDPLT.

2.Do not program the Direct in Termination service data against the route assigned by this command.

3.Parameters

RT:

Route Number (Must be Ring Down Trunk)

TN:

Tenant Number of Monitored Number

MNO:

Monitored Number (as programmed in AMNO)