NEC 2400IMX system manual Acdcom ACD Communications Data, Programming

Models: 2400IMX

1 485
Download 485 pages 63.2 Kb
Page 436
Image 436

ACDCOM: ACD COMMUNICATIONS DATA

ACDCOM: ACD Communications Data

1.Function

This command is used to set up the I/O ports that are to be used for the Management Information Service(s) (MIS) and for Infolink.

Communication Data

I/O Ports

Trace Parameters

Type Speed

 

Update

 

 

1

Call Process-

2

ing

Close

 

 

3

MIS Errors

 

List

4

Trace Destination

 

5

Buffer

I/O Port

 

6

 

 

 

Clock Adjustment

Update Communication?

 

 

2.Parameters

I/O Ports:

1 to 6

I/O Type:

MIS-1, MIS-2, MIS-3, MIS-4, MIS-5, Infolink, and OFF

I/O Speed:

4-64 ms (standard assignment = 64)

Trace Parameters:

Call Processing: On/Off

MIS Errors: On/Off (Normally set to “OFF”)

X409 Messages: On/Off

Trace Destination: I/O Port Number (1 to 6) / Buffer (Normally set to “Buffer”)

Clock Adjustment: 1 to 9999 (default 1049)

3.Programming

The type of MIS will determine how the I/O ports are programmed.

MIS-1:

not supported

MIS-2:

Navigator and Abacus MIS

MIS-3 ~ MIS-5:

reserved for future use

Infolink:

for Infolink clients (ACD Release 3 and above)

NDA-24282

CHAPTER 7