ACNOL: Assignment of Conversion Number Data for LDM

ACNOL: Assignment of Conversion Number Data for LDM

1.Function

ACNOL is used to direct a specified ringdown type trunk route to a specific monitored number (monitored number is the same as a pilot number) in Telephone number. The conversion number programmed in ACNOL is available for the self node only.

Note: This command does not apply to self-directing type trunks (i.e. DID, TIE Lines, etc.).

2.Precautions

1.Prior to this command, program the monitored number by AMNOL and ACDPLT.

2.Assign the logical route number against each physical route number in ALRTL.

3.Do not program the Direct-in Termination service data against the route assigned by this command.

3.Parameters

LGRT:

Logical Route Number 1-254 (Must be Ring Down Trunk)

UGN:

User Group Number of Monitored Number (Fixed “1”)

L_MNO:

Telephone number of Local Monitored Number (as programmed in AMNOL)

CHAPTER 7

NDA-24282 (E)

Page 362

 

Revision 1.0

 

Page 381
Image 381
NEC 2400IMX Acnol Assignment of Conversion Number Data for LDM, Lgrt, Logical Route Number 1-254 Must be Ring Down Trunk