ACNON: Assignment of Conversion Number Data for NDM

ACNON: Assignment of Conversion Number Data for NDM

1.Function

ACNON is used to direct a specified ringdown type trunk route to a specific monitored number (monitored number is the same as a pilot number) in Telephone number. The monitored number is available for all nodes within Fusion network.

Note: This command does not apply to self-directing type trunks (i.e. DID, TIE Lines, etc.).

2.Precautions

1.Prior to this command, program the monitored number by AMNON and ACDPLT.

2.Assign the logical route number against each physical route number in ALRTN.

3.Do not program the Direct-in Termination service data against the route assigned by this command.

3.Parameters

LGRT:

Logical Route Number 1-254 (Must be Ring Down Trunk)

UGN:

User Group Number of Monitored Number (Fixed “1”)

N_MNO:

Telephone number of Network Monitored Number (as programmed in AMNON)