NEC 2400IMX system manual Installation Upgrading Procedure

Models: 2400IMX

1 485
Download 485 pages 63.2 Kb
Page 58
Image 58
Note 1
Note 2

INSTALLATION

5.2 UPGRADING PROCEDURE

STEP 1 : Print out the existent data in the MIS terminal or save the data as the text file.

Note 4

STEP 2 : List up the office data related to the current ACDP.

STEP 3 : Shutdown MIS operation following the appropriate procedure.

Note 4

STEP 4 : Make busy the CPU (ACDP) card (CP53/CP54) and disconnect all cables connected to cards related to ACD.

STEP 5 : Upgrade the PBX hardware following the Upgrade Manual for the PBX.

STEP 6 : Install the software below to upgrade the PBX software. Refer to Chapter 3, Section 4.1, “ACD Software Installation”.

• An assortment of software for NEAX2400 IMX

Built-in ACDP software

• System Configuration Software containing ACD Options

STEP 7 : Program the following ACD commands data again.

ACDTN/ACDSPL/ACDLOG/ACDPSN/ACDCCV/ACDPLT/ACDTG/ACDANA/ACDIVR/

ACDHS/ACDHC/ACDWS

STEP 8 : Start up the Navigator MIS for IBMPC/AT.

Note 3

Standard MIS hardware and software

MIS terminal hardware and software

STEP 9 : Start up the IVR/Host.

Note 4

IVR/Host hardware and software

Related Equipment for LAN

STEP 10 : Perform the installation test.

Note 1: When ACD service is used in a Fusion Network, and when “ACD Trunk in aFusion Network” is used: Install the software into the node that accommodates the ACDP.

When “AGENT ANYWHERE” is used:

Install the software into one node only. In this case, the node with the most ACD agent positions is recommended to prevent network traffic congestion. The node that uses the ACDP is most recommended according to the service condition Item 3 described in “Agent Anywhere - ACD” in Chapter 5.

Note 2: When ACD features are activated in Fusion network, this software is installed in all nodes.

Note 3: This procedure is not necessary for the ACD without MIS.

Note 4: Details for start-up procedure are decided by the IVR/Host feature specifications. This procedure is not necessary when IVR/Host is not used.

NDA-24282CHAPTER 3

Page 39

Revision 1.0

Page 58