ASYD: ASSIGNMENT OF SYSTEM DATA

ASYD: Assignment of System Data

1.Function

This command is used to assign and change system data in the NEAX2400 IMX.

2.Precautions

1.ASYD is divided into three sections, as follows:

a.Assignment of System Data-1.

(SYS 1) - System-wide control parameters.

b.Assignment of System Data-2.

(SYS 2) - Service feature availability, on a tenant basis.

c.Assignment of System Data-3.

(SYS 3) - System-wide ringing patterns and hookswitch timing.

2.Only ASYD System Data-1 parameters relate to the functioning of ACD system.

3.System data must be entered using hexadecimal numbers. Refer to the ACD system Job Specification for the applicable system data.

3.Parameters

SYS:

System Data Items

 

1: System Data 1

 

2: System Data 2

 

3: System Data 3

TN:

Tenant Number

INDEX:

System Data Index

 

SYS

INDEX

 

1

0-511

 

2

0-15

 

3

0-31

DATA:

System Data (Hexadecimal)

CHAPTER 7

NDA-24282

Page 334

Revision 1.0

Page 353
Image 353
NEC 2400IMX system manual Asyd Assignment of System Data, SYS Index