PA-PC56-A (COPY)

5.Switch Settings

Standard settings of various switches on this circuit card are shown in the table below.

SWITCH

SWITCH NO.

SETTING

STANDARD

 

 

 

MEANING

NAME

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MB

 

UP

 

 

Circuit card make busy.

 

 

 

 

 

 

 

 

DOWN

 

 

Circuit card make idle.

 

 

 

 

 

 

 

 

 

 

 

 

SREQ

 

UP

 

 

Separate mode request.

 

 

 

 

 

 

 

 

DOWN

 

 

Separate mode request cancel (Copy mode).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

To be set in the case of System No. 0.

 

 

 

 

(To be mounted in Slot No. 08 of APMA.)

 

1

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

To be set in the case of System No. 1.

 

 

 

 

 

 

 

 

(To be mounted in Slot No. 17 of APMA.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW0

3

OFF

 

 

 

 

 

 

 

 

 

 

 

 

4

OFF

 

 

 

Fixed

 

 

 

 

 

 

 

 

5

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

7

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

8

ON

 

 

 

 

 

 

 

 

 

 

 

 

CHAPTER 4

NDA-24282

Page 70

Revision 1.0

Page 89
Image 89