PA-4DATA (4DAT)

5.Switch Settings

Standard settings of various switches on this circuit card are shown in the table below.

SWITCH

SWITCH NO.

SETTING

STANDARD

MEANING

NAME

SETTING

 

 

 

MB (SW11)

 

UP

 

 

 

 

Circuit card make busy.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN

 

 

Circuit card make idle.

 

 

 

 

SW1 (for Cir-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SETTING OF TIMER FOR EACH CIRCUIT

 

cuit No. 0)

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

3

 

4

TIMER (MODE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW2 (for Cir-

 

 

 

 

 

 

 

ON

 

ON

 

OFF

 

ON

16-sec. mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

ON

 

ON

 

OFF

32-sec. mode

 

cuit No. 1)

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

OFF

 

OFF

 

OFF

60-sec. mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW3 (for Cir-

 

 

 

 

 

 

 

Note 1: 16-sec. mode = 4 recording circuits

 

 

 

 

 

 

 

cuit No. 2)

3

 

 

 

 

 

 

 

 

32-sec. mode = 2 recording circuits

 

 

 

 

 

 

 

 

 

 

60-sec. mode = 1 recording circuit.

SW4 (for Cir-

 

 

 

 

 

 

 

Note 2: For each circuit, SW1 ~ SW4 must be set

 

 

 

 

 

 

 

cuit No. 3)

4

 

 

 

 

 

 

 

 

in the same way. (Two different modes

 

 

 

 

 

 

 

 

 

 

cannot be assigned.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SETTING OF ANNOUNCEMENT RECORDING/

 

 

1

 

 

 

 

 

 

PLAYBACK TIME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW5-1

 

 

SW5-2

 

RECORDING/PLAYBACK TIME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

ON

 

16-sec. Recording/Playback

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

OFF

 

32-sec. Recording/Playback

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

OFF

 

60-sec. Recording/Playback

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 3: Set the Recording/Playback Timer in the same way as set by

 

 

 

 

 

SW1 ~ SW4.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

ON

 

 

To be used by -Law.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

To be used by Α

-Law.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

ON

 

 

 

 

When using as an external hold tone source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

When using as announcement equipment only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHAPTER 4