3. Hardware Installation

Installation

10.ScreenPRO-II Connections — if your system includes one (or more) destination ScreenPRO-II units, you can configure the units for internal or external routing:

a.When External routers are used, connect two outputs from an Analog router to any two HD-15 inputs on the ScreenPRO-II. An SDI router can also be connected to BNC inputs 1 and 2. During setup, these specific patches will be defined using the Output Patch Menu.

b.When Internal routing is used, connect Analog sources to inputs 1 - 8 on the HD-15 connectors, and SDI sources to BNC inputs 1 and 2. During setup, these patches will be defined using the Input Patch Menu.

In Chapter 6, see the ScreenPRO-II Destination Setup” section for details.

11.Output Connections — all output monitor and projector connections originate from the “top stack” processor:

a.Connect the analog or digital Preview Output to the input of the associated Preview Monitor.

b.Connect the analog or digital Program 2 Output to the input of the associated Program Monitor.

c.Connect the analog or digital Program 1 Output to the input of the associated projector.

d.Connect the Program Out HD/SDI connector to an SDI or HDTV monitor as required, or to the proper video distribution equipment.

Note

This output only works if the selected output resolution is a valid SDI or HD/SDI format.

e.If you elect to output in an interlaced format (e.g., 1920 x 1080i), connect the top stack’s H Sync Output signal (located on the Program 2 Out Analog connector) to the Genlock input on the bottom stack.

Note

Using a VGA to 5xBNC breakout cable, the H Sync Output line is typically a white or gray cable.

12.Aux Destinations — you can configure three types of Aux destinations: Aux (monitors), ImagePRO Aux and PresentationPRO-II Aux. Refer to Appendix D, Working With Destinations” on page 393 for interconnection details.

13.Power Connection — connect AC to all Encore and peripheral equipment.

14.Tally Connection — the Controller provides one 25-pin D connector for issuing “relay closure” commands to external devices. Eight circuits are provided. In Appendix A, refer to the “Tally Connector” section on page 374 for details.

15.System ID — Using the Unit ID Selector, set the ID of the bottom stack processor (VP only) to 1. Set the ID of the top stack processor to 2 (VP or VPx).

Important

The ID of the bottom stack processor must always be lower than the ID of the top stack processor. Remember that Master units (ID#1 and ID#2) must be VP, not VPx.

16.Power On — all power on instructions are covered in Chapter 6. Continue with Chapter 4, Controller Orientation” on page 107.

Encore Presentation System • User’s Guide • Rev 04

 

83

 

Page 83
Image 83
Barco 26-0313000-00 manual Installation