3. Hardware Installation

Installation

Note

Connect the computer’s “head 3” to processor 3, input 3A

Input 3A resides on the lowest priority M/E in a 3 M/E system. To connect a second background, use input 3B.

d.The DSK source may originate from a computer with a multi-head graphics card, but it is not a requirement.

S Connecting a single-head graphics card to processor 3 only would enable a bug to be placed only in that screen space.

Note

The DSK Setup Menu allows you to pick an individual ID

 

within a widescreen on which to perform DSK setup.

 

 

To use a multi-head graphics card for the DSK, connect it to the same input on each VP or VPx — to the highest priority M/E (M/E 1).

STo connect an unscaled DSK source in a triple processor system (each processor with three M/Es):

Note

Connect the computer’s “head 1” to processor 1, input 1A Connect the computer’s “head 2” to processor 2, input 1A

Connect the computer’s “head 3” to processor 3, input 1A

Input 1A resides on the highest priority M/E in a 3 M/E Encore system. If you wish to connect a backup DSK, use input 1B.

7.D/A Connections —

a.If your system includes analog, SDI or DVI D/As, connect video inputs to the D/As as required.

b.Connect D/A outputs to the to the desired M/E input connectors.

8.Router Connections — if you elect to use router connections, in place of (or in addition to) direct connections:

a.For Ethernet controlled routers, ensure that they are connected to the same Switch as the Controller and processors. Ensure that each router has an unique IP address.

b.To connect a single serial controlled router, use an RS-232 cable to connect the router to the Controller’s EXT COMM port. In Chapter 2, refer to the “Controller Rear Panels” section on page 58 for details.

c.To connect two (or more) serial routers, a third-party Ethernet-to-Serial converter is required, such as the Lantronix model UDS100, UDS200 or UDS2100 (http://www.lantronix.com). Note that each UDS2100 can control two serial routers.

Using RS-232 cables, connect each router to the UDS2100.

Set up a static IP address on the Lantronix. The recommended range is 192.168.0.191 - 192.168.0.240. Refer to the Lantronix User’s Guide for instructions.

Using an Ethernet cable, connect the UDS2100 to the same switch as the Controller and processors.