Encore Presentation System • User’s Guide • Rev 04 397
aK==tçêâáåÖ=táíÜ=aÉëíáå~íáçåë
ScreenPRO-II Configurations
bñíÉêå~ä=pÉêá~ä=~åÇ=bíÜÉêåÉí=oçìíÉê=`çåÑáÖìê~íáçå
The diagram below shows a configuration that uses two ScreenPRO-II units with external
source routing. Each ScreenPRO-II is set up as a unique destination. One external
Ethernet router is used, and one external serial router is used.
Figure D-4. ScreenPRO-II units using external serial and Ethernet routers
For an “external routing” configuration with Ethernet controlled routers, please note the
following points regarding destination setup and source connections:
On the Destination Setup Menu:
~Select Single Screen SP as the “Type.”
~Set the “Routing Mode” to External.
~In Chapter 6, refer to the “ScreenPRO-II Destination Setup” section on
page279 for instructi ons.
Connect analog and digital sources to each router in the normal manner.
For each router, connect two outputs to each ScreenPRO-II.
On the Router Specification Menu, select the correct router and manufacturer.
In Chapter 6, refer to the “Router Setup” section on page270 for instructions.
~For the serial router, set the “Communication Type” to RS-232.
~For the Ethernet router, set the “Communication Type” to ETHERNET.
Router outputs are mapped using the Output Patch Menu. This menu defines
which router output connects to which ScreenPRO-II input. In Chapter 6, refer to
the “Router Setup” section on page 270 for instructions.
Router inputs are mapped using the Input Patch Menu. In Chapter 6, refer to the
Output Format Setup” section on page285 for instru ctions.
Ext Comm
MatrixPRO SDI Router
MatrixPRO Analog Router
Encore Controller (SC or LC)
ScreenPRO-II
Ethernet Switch
Side Screen 1
Side Screen 2
Router
Outputs
Inputs
SDI
Inputs
Analog
Inputs
RS-232