Note

bK==^ééäáÅ~íáçå=kçíÉë

Encore Controller to Router Connections

RS-232 cable requirements vary. Use the table in the following section for specific cable requirements for various routers.

oçìíÉê=`çååÉÅíáçå=q~ÄäÉ

The table below illustrates numerous notes and cable requirements, when connecting Encore to various routers.

Table E-5.Router Connection Table

 

 

straight through cable

 

null modem cable

 

Router

 

Use

 

Use

Note

 

 

 

 

Sierra

 

 

 

 

Use Host Connector

 

 

 

 

 

Ensure DIP switches on Control Processor are set correctly

 

 

 

 

 

 

Older models

 

 

 

 

TX out of Sierra on Pin 2

 

 

 

 

 

 

 

 

 

 

 

RX in to Sierra on Pin 6

 

 

 

 

 

 

 

 

 

 

 

GND on Pin 1

 

 

 

 

 

 

New models

 

 

3

 

… when connecting to Encore Controller

 

 

 

 

 

 

 

3

 

 

 

… when connecting to Lantronix

 

 

 

 

 

 

Leitch

3

 

 

 

… when connecting to Encore Controller

 

 

 

 

 

 

 

 

 

3

 

… when connecting to Lantronix

 

 

 

 

 

 

Extron

 

 

3

 

… when connecting to Encore Controller

 

 

 

 

 

 

 

3

 

 

 

… when connecting to Lantronix

 

 

 

 

 

 

 

 

 

 

 

Direct Ethernet connections are supported

 

 

 

 

 

 

DPI or DVILINK

3

 

 

 

… when connecting to Encore Controller

 

 

 

3

 

… when connecting to Lantronix

 

 

 

 

 

 

Folsom

3

 

 

 

Use straight DB-25 to DB-9 cable to Encore Controller

 

 

 

 

 

 

 

3

 

3

 

Use straight DB-25 to DB-9 cable plus null modem adapter to

 

 

 

 

 

Lantronix

 

 

 

 

 

… or, use direct Ethernet to router