Siemens SITRANS FUS1010 NEMA-4X/ IP 65 manual Flow Data Menu Items, Vs m/s

Models: SITRANS FUS1010 NEMA-4X/ IP 65

1 232
Download 232 pages 51.98 Kb
Page 105
Image 105

Section 2

1010NFM-3J

 

 

 

 

 

 

 

FLOW DATA MENU ITEMS

 

 

Flow

This is a real-time (updated) flow rate display in current rate units

 

 

 

 

(e.g., GAL/MIN).

 

 

 

Flow Vel F/S

Linear fluid flow velocity in f/s or m/s depending on preferred units.

 

 

 

Total

This is a real-time (updated) flow total display in current total units

 

 

 

 

(e.g., KGAL).

 

 

 

Vs m/s

Current liquid sonic velocity (Vs) in m/s. The Vs value depends on the liquid

 

 

 

 

and its temperature. This menu cell allows “fine-tuning” when highlighted.

 

 

 

 

Press the [+] key (coarse adjustment) or the [1] key (fine adjustment) to

 

 

 

 

increase the reading, or the [-] key (coarse adjustment) or the [2] key (fine

 

 

 

 

adjustment) to decrease the reading.

 

 

 

 

CAUTION: Incorrect usage will result in reduced accuracy.

 

 

 

Signal (mV)

Xdcr signal strength (in mV). This is the amplitude of the transittime receive

 

 

 

 

signals. Improper coupling, attenuative liquid or pipe could cause a low value.

 

 

 

Valc %

Input Amplifier gain indication. Larger % indicates a stronger liquid signal.

 

 

 

Vaer %

This shows the current percent of aeration detected by the meter.

 

 

 

Alarm Status

This letter code field shows the status of the meter’s built-in alarms.

 

 

 

 

A dash indicates an inactive alarm. Letter codes reflect the following

 

 

 

 

alarm conditions:

 

 

 

 

S = Transducer Spacing Warning

 

 

 

 

E = Empty Alarm

 

 

 

 

R = Flow Rate Alarm (High or Low rate threshold exceeded)

 

 

 

 

F = Fault Alarm

 

 

 

 

A = Aeration Alarm

 

 

 

 

M = Memory Activated (Fault Suppressed)

 

 

 

 

K = Makeup Flag (May be Latched)

 

 

 

 

I = Interface Alarm

 

 

 

 

P = Pig Alarm (option)

 

 

 

 

Z = ZeroMatic alarm

 

 

 

AnCal

Flow Rate Simulator for calibrating external devices, etc. Highlight this item

 

 

 

 

then press the Right Arrow to enable numeric entry. Type desired simulated

 

 

 

 

flow rate. Be aware of the units prefix (K, M, etc.).

 

 

 

 

NOTE: AnCal remains active only while you remain in this menu cell.

 

 

 

HiFlow

Most positive expected flow rate for application (adjustable).

 

 

 

GAL/MIN

 

 

 

 

LoFlow

Most negative expected flow rate for application (adjustable).

 

 

 

GAL/MIN

 

 

Vs m/s

This menu cell shows the current sonic velocity in m/s. If you move the cursor to this menu cell you will note that it switches from the usual arrow ( ) to a question mark (?). This indicates that you can increase the reading by pressing the [+] key for coarse adjustment or the [1] key for fine adjustment; or reduce the reading by pressing the [-] key for coarse adjustment or the [2] key for fine adjustment. Sonic velocity (Vs) adjustment is a diagnostic tool intended for our technicians or experienced users only. Improper use will affect the meter accuracy.

2-65