Section 2 | ||||
|
|
|
|
|
|
| FLOW DATA MENU ITEMS | ||
|
| Flow | This is a |
|
|
|
| (e.g., GAL/MIN). |
|
|
| Flow Vel F/S | Linear fluid flow velocity in f/s or m/s depending on preferred units. |
|
|
| Total | This is a |
|
|
|
| (e.g., KGAL). |
|
|
| Vs m/s | Current liquid sonic velocity (Vs) in m/s. The Vs value depends on the liquid |
|
|
|
| and its temperature. This menu cell allows |
|
|
|
| Press the [+] key (coarse adjustment) or the [1] key (fine adjustment) to |
|
|
|
| increase the reading, or the |
|
|
|
| adjustment) to decrease the reading. |
|
|
|
| CAUTION: Incorrect usage will result in reduced accuracy. |
|
|
| Signal (mV) | Xdcr signal strength (in mV). This is the amplitude of the transittime receive |
|
|
|
| signals. Improper coupling, attenuative liquid or pipe could cause a low value. |
|
|
| Valc % | Input Amplifier gain indication. Larger % indicates a stronger liquid signal. |
|
|
| Vaer % | This shows the current percent of aeration detected by the meter. |
|
|
| Alarm Status | This letter code field shows the status of the meter’s |
|
|
|
| A dash indicates an inactive alarm. Letter codes reflect the following |
|
|
|
| alarm conditions: |
|
|
|
| S = Transducer Spacing Warning |
|
|
|
| E = Empty Alarm |
|
|
|
| R = Flow Rate Alarm (High or Low rate threshold exceeded) |
|
|
|
| F = Fault Alarm |
|
|
|
| A = Aeration Alarm |
|
|
|
| M = Memory Activated (Fault Suppressed) |
|
|
|
| K = Makeup Flag (May be Latched) |
|
|
|
| I = Interface Alarm |
|
|
|
| P = Pig Alarm (option) |
|
|
|
| Z = ZeroMatic alarm |
|
|
| AnCal | Flow Rate Simulator for calibrating external devices, etc. Highlight this item |
|
|
|
| then press the Right Arrow to enable numeric entry. Type desired simulated |
|
|
|
| flow rate. Be aware of the units prefix (K, M, etc.). |
|
|
|
| NOTE: AnCal remains active only while you remain in this menu cell. |
|
|
| HiFlow | Most positive expected flow rate for application (adjustable). |
|
|
| GAL/MIN |
|
|
|
| LoFlow | Most negative expected flow rate for application (adjustable). |
|
|
| GAL/MIN |
|
|
Vs m/s
This menu cell shows the current sonic velocity in m/s. If you move the cursor to this menu cell you will note that it switches from the usual arrow ( ) to a question mark (?). This indicates that you can increase the reading by pressing the [+] key for coarse adjustment or the [1] key for fine adjustment; or reduce the reading by pressing the