6.6SPECIFICATIONS – TEFLON PFA FLOW TUBE
*Typical values, subject to change without notice
| Size 1 | Size 2 |
Liquid | Must be compatible with PFA under | Must be compatible with PFA under |
| operating conditions and free of sus- | operating conditions and free of |
| pended gasses or solids. | suspended gasses or solids. |
|
|
|
Pressure Drop | 0.23 psi @ 1.0 GPM (3.8 LPM) | 0.23 psi @ 3.0 GPM (11.4 LPM) |
| flowing water at 68°F | flowing water at 68°F |
|
|
|
Sensitivity | 0.0004 GPM (0.0015 LPM) | 0.001 GPM (0.004 LPM) |
Linearity | 1% of flow for rates above 0.07 GPM | 1% of flow for rates above 0.27 GPM |
| (0.26 LPM) | (1.00 LPM) |
|
|
|
Repeatability | ±0.2% of flow for rates above 0.6 | ±0.2% of flow for rates above 1.5 GPM |
| GPM (2.3 LPM) | (5.7 LPM) |
|
|
|
Zero Stability | ±0.001 GPM (0.0038 LPM) | ±0.003 GPM (0.012 LPM) |
Accuracy, | ±1% of flow over 0.15 GPM (0.57 | ±1% of flow over 0.5 GPM (1.9 LPM) to |
Intrinsic | LPM) to 5 GPM (20 LPM) | 16 GPM (60 LPM) |
Accuracy, Flow | ±0.5% of flow over 0.15 GPM (0.57 | ±0.5% of flow over 0.5 GPM (1.9 LPM) |
Calibrated | LPM) to 5 GPM (20 LPM) | to 16 GPM (60 LPM) |
Connection | 1/ ” Flaretek Ultrapure PFA Tube | 3/ ” Flaretek Ultrapure PFA Tube |
| 2 | 4 |
| Fitting | Fitting |
6.7SPECIFICATIONS – 316 STAINLESS STEEL FLOW TUBE
*Typical values, subject to change without notice
| Size 1 | Size 2 |
Liquid | Must be compatible with 316SS | Must be compatible with 316SS under |
| under operating conditions and free | operating conditions and free of sus- |
| of suspended gasses or solids. | pended gasses or solids. |
|
|
|
Pressure Drop | 0.21 psi @ 1.6 GPM (6.0 LPM) | 0.20 psi @ 4.5 GPM (17.0 LPM) |
| flowing water at 68°F | flowing water at 68°F |
|
|
|
Sensitivity | 0.0005 GPM (0.002 LPM) | 0.0015 GPM (0.0057 LPM) |
Linearity | 1% of flow for rates above 0.1 GPM | 1% of flow for rates above 0.3 GPM |
| (0.38 LPM) | (1.1 LPM) |
|
|
|
Repeatability | ±0.2% of flow for rates above 0.5 | ±0.2% of flow for rates above 1.5 |
| GPM (1.9 LPM) | GPM (5.7 LPM) |
|
|
|
Zero Stability | ±0.001 GPM (0.0038 LPM) | ±0.004 GPM (0.015 LPM) |
Accuracy, | ±1% of flow over 0.13 GPM (0.57 | ±1% of flow over 0.4 GPM (1.5 |
Intrinsic | LPM) to 10 GPM (40 LPM) | LPM) to 30 GPM (114 LPM) |
Accuracy, Flow | ±0.5% of flow over 0.13 GPM (0.5 | ±0.5% of flow over 0.4 GPM (1.5 |
Calibrated | LPM) to 10 GPM (38 LPM) | LPM) to 30(114 LPM) |
Connection | 5/ ” Swagelok Tube Fitting | 1” Swagelok Tube Fitting |
| 8 |
|