2.11.3 THE APPLICATION INFO MENU

This menu provides a live display of the basic timing data used by meter during operation.

 

 

Siemens

2 Channel [1]

1

 

 

 

 

 

 

Time between transit and receive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TN uSec

 

75.193

 

 

 

 

 

 

 

TL uSec

 

44.009

 

 

 

 

 

 

 

DeltaT uSec

 

126

 

 

 

 

 

 

 

Burst/Sec

 

256

 

 

 

 

 

 

 

% Accepted

 

100

 

 

 

 

 

 

 

Last Makeup

 

(Re)Start

 

 

 

 

 

 

 

Makeup Status

Measurement

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Application Info

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPLICATION INFO MENU ITEMS

 

 

 

 

TN uSec

The total elapsed time between the transmission and reception of a sonic pulse.

 

TL uSec,

The total time a sonic pulse takes to travel through the liquid.

 

DeltaT nSec

This is the instantaneous result of subtracting the down from the up transit times.

 

 

NOTE: This will appear to be more active than dampened flow readings.

 

Burst/Sec

Number of transmissions per second under current operating conditions.

 

 

The following factors influence this parameter: aeration, pressure transients,

 

 

signal strength variation.

 

 

 

 

 

 

 

% Accepted

The running tally of accepted and rejected up/down transmit burst sets.

 

Last Makeup

Reason for last Makeup (signal reacquisition).

 

Makeup Status

Current stage of Makeup routine. [Measurement = normal operation]

 

 

2.11.4 THE LIQUID DATA MENU

This menu shows the current Reynolds number used by the meter to implement flow profile compen- sation. Depending on the 1010 model, Temp 1 & 2, Viscosity cP, Viscosity cS and Pressure are also offered.

LIQUID DATA MENU ITEMS

Temp 1

Current Liquid Temperature

Temp 2

Current Liquid Temperature

Reynolds #

Current Reynolds number

 

Specific Gravity

Current specific gravity

 

 

Viscosity cP

The absolute viscosity of a liquid dynamically measured in centipoise.

 

Pressure

Derived spanned from analog input.

 

Viscosity cS

Kinematic viscosity of a liquid measured in centistokes.

 