Siemens SITRANS FUS1010 NEMA-4X/ IP 65 NFM-3J System 1010 Analog Outputs, Vfo, Vfab, Valc, Vaer

Models: SITRANS FUS1010 NEMA-4X/ IP 65

1 232
Download 232 pages 51.98 Kb
Page 99
Image 99

Section 2

 

1010NFM-3J

 

 

 

 

 

 

 

 

 

 

 

System 1010 Analog Outputs

 

 

Io (Isolated current)

 

4 to 20 mA varies in proportion to an assigned data function.

 

 

 

Vo (DC voltage)

 

0 to 10 Vdc varies in proportion to an assigned data function.

 

 

 

Pgen (TTL logic)

 

0 to 5000 Hz varies in proportion to an assigned data function.

 

 

 

 

Analog Out Setup Data Categories

 

 

 

Vfo

 

Spanned volumetric/mass flow rate

 

 

 

 

Vfab

 

Spanned unsigned flow magnitude

 

 

 

 

 

Vs

 

Spanned liquid sonic velocity

 

 

 

 

 

Valc

 

Receive signal amplitude

 

 

 

 

 

 

Vaer

 

Relative degree of liquid aeration/cavitation

 

 

 

 

 

Vsg

 

Spaned specific gravity

 

 

 

 

 

Viscosity

 

System liquid viscosity

 

 

 

 

 

T1

 

Current liquid temperature

 

 

 

 

 

Iin1, Iin2

 

Represents a re-transmit of the analog input signals (e.g.,

 

 

 

 

 

 

 

 

Pressure and Temp inputs can be transmitted on the 4/20

 

 

 

 

 

 

 

mA output.)

 

 

 

 

Iin3, Iin4

 

Same as Iin1 and Iin2 above but only available for opera-

 

 

 

 

 

 

 

 

tion in Multi-Beam and Arithmetic modes.

 

NOTE: For Multi-Channel meters, refer to drawing 1010MN-7 for details. For Expanded I/O modules, refer to drawing 1010N-7-7 and Addendum 1010FMA-14 for details.

Table To Determine Proper I/O Installation Drawings

Model Number and I/O Module

Installation Drawing and Page Number*

1010N

1010N-2-7 (Sheet 2 of 2)

1010N with 1010N-7 Expanded I/O Module

1010N-7-7 (Sheet 2 of 3)

1010DN

1010N-2-7 (Sheet 2 of 2)

1010DN with 1010N-7 Expanded I/O Module

1010N-7-7 (Sheet 2 of 3)

*Note: For Ultra Precsion transducers see 1010N-7-7 (sheet 3 of 3).

Assigning Io Output Functions

The Io analog output is a self-powered, isolated 4-20mA DC signal that varies linearly in relation to a selected data function.

CAUTION: Do not connect to a powered loop.

To assign a function for the current output:

From [Analog Out Setup], press twice to access the [Io] option list.

To move the cursor to the desired data function press

To store selection press ENT

2-59

Page 99
Image 99
Siemens SITRANS FUS1010 NEMA-4X/ IP 65 NFM-3J System 1010 Analog Outputs, Analog Out Setup Data Categories, Vfo, Vfab, Vsg