Next, we will pick the pipe size: [1CS80] by moving the cursor to the selection and then press- ing ENT . This is all there is to setting up the pipe parameters.

Now, we will select and install the transducers.

Siemens

1.8.2 PICKING AND INSTALLING THE TRANSDUCERS

Press to access the Pick/Install Xdcr menu, then select the appropriate Transducer Model. The meter then analyzes your pipe data and registered transducer list before calculating the recommended transducer size(s). The top-line prompt shows a series of transducer recommendations, that are listed in order of priority from left to right. Select the appropriate transducer size with consideration given to the computed transducer recommendations. In the example below we will install the “B3” transducer size.

After you make your transducer selection, the meter automatically computes the preferred mounting mode and transducer spacing index.

Siemens

NOTE: The meter only indicates the part number of the 1011 Universal Transducer mounting track or spacer bar. It does not indicate this information for other transducer types.

Note the Number Index value.

This value corresponds to the index marked on the spacer bar or mounting track. The value of Ltn represents the actual distance in inches or mm, between the front surfaces of the upstream and downstream transducers.