Section 2

 

 

 

 

1010NFM-3J

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE I/O DATA CONTROL MENU STRUCTURE

 

 

 

 

 

 

 

 

 

 

I/O Data Control

Analog Output Setup

Io1/Io2

 

 

Vfo

 

 

 

 

 

 

 

 

Vfab

 

 

 

 

 

 

 

 

Vs

 

 

 

 

 

 

 

 

Valc

 

 

 

 

 

 

 

 

Vaer

 

 

 

 

 

 

 

 

Vsg

 

 

 

 

 

 

 

 

Viscosity

 

 

 

 

 

 

 

 

T1

 

 

 

 

 

 

 

 

Iin1

 

 

 

 

 

 

 

 

Iin2

 

 

 

 

 

 

 

 

Iin3*

 

 

 

 

 

 

 

 

Iin4*

 

 

 

 

 

Vo1/Vo2

 

 

See Io option list

 

 

 

 

 

 

 

Pgen1

 

 

See Io option list

 

 

 

 

 

 

 

Relay Setup

Relay 1

 

 

Off

 

 

 

 

 

 

 

 

 

 

 

Power On

 

 

 

 

 

 

 

 

S.G.

 

 

 

 

 

 

 

 

Hi Temperature

 

 

 

 

 

 

 

 

low Temperature

 

 

 

 

 

 

 

 

High Flow

 

 

 

 

 

 

 

 

Low Flow

 

 

 

 

 

 

 

 

Flow Alarm

 

 

 

 

 

 

 

 

Fault Alarm

 

 

 

 

 

 

 

 

Spacing

 

 

 

 

 

 

 

 

Empty

 

 

 

 

 

 

 

 

Aeration

 

 

 

 

 

 

 

 

Interface

 

 

 

 

 

 

 

 

Reverse Flow

 

 

 

 

 

 

 

 

BatchTot

 

 

 

 

 

 

 

 

Pos Total

 

 

 

 

 

 

 

 

Neg Total

 

 

 

 

 

 

 

 

Soft Fault (Multi-beam)

 

 

 

 

 

Relay 2

 

 

See Relay 1 list for 2, 3 & 4

 

 

 

 

 

Analog Input Setup

Iin1

Input

Off

 

 

 

 

 

 

 

 

 

Aux (X or F-Option)

 

 

 

 

 

 

 

 

S.G. (F-Option)

 

 

 

 

 

 

 

 

cS (F-Option)

 

 

 

 

 

 

 

 

cP

 

 

 

 

 

 

 

 

PSIA (BAR) - (F-Option)

 

 

 

 

 

 

 

 

BARA

 

 

 

 

 

 

 

 

Deg F

 

 

 

 

 

 

 

 

Deg C

 

 

 

 

 

 

4 mA

numeric entry

 

 

 

 

 

 

 

20 mA

numeric entry

 

 

 

 

 

 

Iin2

Input

See Iin1 option list

 

 

 

 

 

 

 

4 mA

numeric entry

 

 

 

 

 

 

 

 

20 mA

numeric entry

 

*For Multi-Path and Arithmetic operating modes only.

2.10.1 ANALOG OUTPUT SETUP

System 1010 provides current, voltage and pulse-rate analog outputs. Analog Output Setup allows you to assign data functions for these signals. The flow computer’s terminal strip contains the analog output terminals.

2-58

Page 98
Image 98
Siemens SITRANS FUS1010 NEMA-4X/ IP 65 manual Analog Output Setup, I/O Data Control Menu Structure