Appendix

1010NFM-3J

 

 

Due to the different System 1010/1020 meter configurations, there are 3 types of RS-232 communica- tion cables employed. You can determine which cable is required for the your model flowmeter from the table below. Be sure you have the appropriate cable available for use.

Meter Type

Cable Type

Controlotron Part Number

Notes

Weatherproof Portable

DB-9F – Amphenol

1015CPC-WP

Except Energy

1010P/1020N

DB-9F

DB-9F

1015CPC-P

Use for Energy WP

All NEMA4X

DB-9F – 3 Wire

1015CPC-N

 

NEMA 4X with Expanded

DB-9F

- DB-9F

1015CPC-P

For 1010N with “A1”

I/O Module

 

 

 

option (1010N-7 module)

All 1010X

DB-9F – 3 Wire

1015CPC-N

 

For those who would prefer to make the cables themselves, the required parts (except for the RS-232 connector for the 1010WP meter types) should be available at most computer or electronics stores. You will find drawings of the terminations for these cables with the reference table below. It provides the signal names, PC termination and 1010/1020 meter termination for each type of flowmeter.

Also, in most computer stores or online, you will be able to find or you may already have a serial “LapLink” cable or “Null Modem” cable. These cables can be used to communicate with the 1010P/ DP and 1020N systems.

If you purchased a 1010W model, you may have received the special connector used for the RS- 232 terminal in a packet included with your 1010W. This will enable you to construct the appropriate cable for this meter type.

If you prefer to construct your own cable, the following conventions apply in the table:

PC: Refers to an IBM compatible, DB-9 serial Com port.

1010N: Includes all models (N, DN, MN, E, EXCEPT those with “A1” option). Termination is made to the 1010N-2 I/O Data Module. Flowmeter end of cable is unterminated wire.

1010N With “A1” Option: Meters that carry ”A1” option have 1010N-7 module installed that houses a DB-9 connector for RS-232 communication.

1010P/1020N: Includes all models (P/DP). Termination is made to the RS-232 port DB-9 connector. A DB-9 Female connector is needed to mate with the meter connector.

1010WP: Includes all models (WP, WDP except energy meters). Termination is made to the RS- 232 port on the connector panel. A special cable terminal is required and can be obtained from Controlotron (Part #1015XWP).

1010X: Includes all models (X, DX). Termination is made to the 1010X-8 I/O module Terminal TB2. Flowmeter end of cable is unterminated wire.