Section 5

1010NFM-3J

 

 

 

 

 

 

 

TERM

EXPLANATION

Local Display

Refers to the 1010N’s integral display screen.

Menu

Sub-sections of the Installation Menu that you to define specific operational

 

functions (e.g., RS-232 Setup).

Menu Cell

A location within a Menu where you define either a single numeric value or

 

option list selection that supports the Sub-Menu’s function. Certain view-only

 

menu cells show reference data appropriate to the current application.

NEGFLOW

Totalizer mode for negative flow total only.

 

NETFLOW

Totalizer mode that combines positive and negative flow totals.

NOTOT

System function that disables the internal Totalizer.

 

Number Index

Computed transducer spacing index based on the estimated sonic velocity

 

measurement. This Index cannot be overridden by installer.

Numeric Data

Refers to a value entered into a menu cell. An example would be the pipe

 

 

outer diameter.

Numeric Entry

Refers to a number you type into menu cell that stores numeric data.

 

Numeric Keys

Use the Numeric keys to type a numeric value where appropriate.

OpSys ROM

The read only memory that stores its basic operating instructions and per-

 

 

manent defaults.

Option List

Lists of options presented at menu cells that allow you to select either a

 

 

single item or multiple items (depending on the function that the menu cell

 

controls).

Parameter

Refers to value (either numeric or list selection) stored in a menu cell.

POSFLOW

Totalizer mode for positive flow total only.

 

Register

Refers to a memory location used by the flow computer to store data such as

 

 

the flow total, etc.

RTD

Temperature sensors used with energy flow of mass flow systems.

Site Name

A user-entered name that meter associates with a stored Site Setup. You

 

retreive a particular Site by selecting its name from a site name list.

Site Setup

A collection of parameters used by the meter to service a specific site (or

 

 

location).1010 allows you to store several independent Site Setups.

Site Storage Memory

Section of RAM allocated for permanent data storage. This memory seg-

 

 

ment stores inactive site setups (including a backup of active site). The meter’s

 

Site Setup storage capacity depends on the dynamic memory allocation as

 

dictated by each application. In addition, the meter uses Site Storage Memory

 

to store configurable operating parameters such as pipe and liquid tables.

Spacing Index

Refers to the Number Index, used by the flow computer to determine the

 

space between the upstream and down stream transducers on clamp-on

 

systems.

Spacing Offset

Fixed transducer offset assigned by the flow computer. This can be overrid-

 

 

den by the installer.

TOTCNT

A totalizer pulse count function used for Batching or Sampling.

Transducer

Clamp-on flow sensors that the meter uses to measure the flow rate.

 

Vaer

The meter’s aeration percent output.

 

Vps

The sonic propagation velocity of a pipe.

 

Vs

The sonic velocity of a liquid.