2.11.7 TROUBLESHOOTING TIPS

The System 1010 has highly reliable circuitry and will provide trouble-free operation within specified environments. Even a well-crafted precision instrument can fail if exposed to extreme temperature or vibration conditions during service, storage or transportation. The Diagnostic menu shows how the system interprets a problem. The test functions and alarm indicators identify “hidden” problems auto- matically. If a problem seems unsolvable, call our Technical Service Department or your local Siemens Ultrasonic Flow Representative for expert help.

Flow Computer Messages

Certain actions or conditions invoke messages that may appear as a pop-up window, in the right-hand column of a given menu cell, or the highlighted prompt line at the top of the display screen. The follow- ing is a list of messages that you may encounter along with explanations, and in some cases, a recom- mended action.

MESSAGE

DESCRIPTION

Memory Full!

 

Response to an attempt to save site data, when data memory is full. Delete

 

 

an obsolete site or clear Datalogger memory to make room for the new

 

 

data.

Memory Corrupted!

Memory read error occurred while accessing the active site data.

Chan Not Setup

Response to an attempt to invoke an operation that requires a channel to

 

 

be enabled. Enable the channel [Channel Setup Channel Enable Yes].

 

 

Note that a channel cannot be enabled until its transducers are operating.

Clr Active Memory?

Response to pressing the F4 key. Use the F4 function to restore operation

 

 

if a severe event (e.g., a violent power surge) disrupts system operation.

Clr Saved Data?

Response to pressing the F4 key, then selecting [No] for Clr Saved Data?

 

 

Yes/No

<EOT>

 

Response to a request to output datalogger data to the printer or the Graph-

 

 

 

ics screen when no datalogger data exists. Set up the Datalogger.

Empty Pipe - Press

Prompt to empty the pipe during the Actual MTY procedure. After emptying

 

 

pipe, press <ENT>.

Fill Pipe - Press [ENT]

Prompt to fill the pipe during the Actual MTY procedure. After filling the pipe,

 

[ENT]

press [ENT] (see paragraph 3.1.3).

No Sites

Response while trying to recall/delete a site setup when no Sites are stored.

Not Installed

 

Response to an attempt to access a menu function that is not included.

Re-space Index

Upon measuring the liquid sonic velocity (Vs), the meter recommends re-

 

 

spacing the transducers to improve performance.

Invalid Setup

 

During the Initial Makeup, the system detects invalid transducer spacing,

(use Direct Mount)

erroneous liquid/pipe parameters, or some other factor that prevents it from

completing the Initial Makeup. This may be due to one of the following:

• An out-of-range data entry.

• An invalid condition (e.g., overlapping transducers in Reflect Mode). If se- lecting Direct Mode does not resolve, review all site setup and transducer installation choices; particularly data entered for the pipe and liquid.

(continued)