Siemens SITRANS FUS1010 NEMA-4X/ IP 65 manual Pipe Data Menu

Models: SITRANS FUS1010 NEMA-4X/ IP 65

1 232
Download 232 pages 51.98 Kb
Page 46
Image 46

Section 2

1010NFM-3J

 

 

 

To Save or Rename a Site Setup:

To access the first character position press

To select a character press then to highlight to next character position.

To select the second character press . Repeat this process to select all the characters (8 max.). To save the site data present in Active Memory press ENT .

2.2THE PIPE DATA MENU

This menu becomes available after picking a Meter Type, Measurement Channel and Measurement Technology. We recommend that you edit the Pipe Data immediately after creating a new Site Setup.

The Pipe Data menu allows you to define the application’s pipe parameters. Select a pipe from one of the meter’s stored pipe tables (see menu structure below); or input the pipe size and description manually. Manual entries include Pipe Material, Outer Diameter (OD) and pipe Wall Thickness. Liner Material and Liner Thickness entries are included to support pipes with liners. The meter requires the pipe outer diameter (OD) and wall thickness to operate. You must define these parameters to com- plete the installation.

The pipe table includes descriptions for over sixty standard pipes plus any user-entered pipes (see Meter Facilities). To use these presets, first pick a Pipe Class (e.g., ASA Stainless Steel), then pick a pipe size within that class (e.g., 4SS10). When you select a particular pipe class/size, the relevant pipe parameters appear in the Pipe Data menu cells. If a given pipe class/size does not match your applica- tion exactly you can still edit each individual parameter to fine-tune your selection. In addition, the Meter Facilities section of the Installation Menu provides a pipe table editor that allows you to customize any or all of the stored pipe tables.

NOTE: If you edit the pipe parameters after the system is operating, you will have to repeat the transducer install procedure.

Use this menu cell to edit the pipe outer diameter.

Use this menu cell to edit the pipe material.

Use this menu cell to edit the wall thickness.

Siemens

2 Channel

[1] ABC

 

 

Select Pipe Class from Pipe Table

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select Pipe Class

Manual Entry

 

 

 

 

Select Pipe Size

No Pipes

 

 

 

 

 

 

 

 

 

 

Pipe OD <in>

 

0.500

 

 

 

 

 

 

Pipe Material

Steel

 

 

 

 

Wall Thickness

0.100

 

 

 

 

 

 

Liner Material

None

 

 

 

 

 

 

 

 

 

 

 

 

Liner Thickness

0.000

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe Data

Use this menu cell to select a Pipe Class from one of the meter's presets. The [Manual Entry] selection (default) means that you enter pipe data manually.

After picking a pipe class, use this menu cell to select a pipe from within that class.

Use this menu cell to select a pipe liner material.

Use this menu cell to edit the pipe liner thickness.

2-6

Page 46
Image 46
Siemens SITRANS FUS1010 NEMA-4X/ IP 65 manual Pipe Data Menu