Siemens SITRANS FUS1010 NEMA-4X/ IP 65 manual Pipe Configuration Menu Structure

Models: SITRANS FUS1010 NEMA-4X/ IP 65

1 232
Download 232 pages 51.98 Kb
Page 59
Image 59

Section 2

1010NFM-3J

 

 

 

2.3.4 PIPE CONFIGURATION

The [Pipe Configuration] menu cell in the Application Data menu presents a list of descriptions of piping configurations that could affect the flow profile characteristics (such as “Single Elbow”). Examine the option list. Selecting a piping configuration that closely approximates conditions at or near your mount- ing location allows the flow computer to compensate for the effect of upstream piping on flow profile. The number of diameters between the upstream configurations and the transducer installation can be numerically entered via the [Anomaly Diams] menu cell.

To select a Piping Configuration:

To access the option list press

To highlight the desired piping configuration press

To register selection press ENT

The default pipe configuration (Fully Developed) wll cause the flowmeter to use the conventional Rey- nolds Compensation Table when compensating for liquid flow profile behavior.

Use this menu cell to enter the number of pipe diameters between the upstream configuration and the transducer installation.

 

 

Siemens

Dual Path

[1]

Path 1

 

 

 

 

Disignate Pipe Shape Near Transducers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid Class

 

 

Water 20C/68F

 

 

 

 

 

UniMass Table

Create/Edit Table

 

 

 

 

 

Temperature Range

-40F to 250F

 

 

 

 

 

Pipe Configuration

Fully Developed

 

 

 

 

 

Anomaly Diams

 

1 Elbow

 

 

 

 

 

 

 

 

 

Dbl Elbow +

 

 

 

 

 

 

 

 

Dbl Elbow -

 

 

 

 

 

 

 

 

Valve

 

 

 

 

 

 

 

 

 

Expander

 

 

 

 

 

 

 

 

 

Reducer

 

 

 

 

 

 

 

 

 

Norm Entry

 

 

 

 

 

 

 

 

Header Inlet

 

 

 

 

 

 

 

 

Intrusions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Application Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use this menu cell to select the pipe configuration that most accurately represents the upstream pipe condition.

Pipe Configuration Menu Structure

Application Data

Pipe Configuration

Fully Developed*

 

(Change to Upstream

1 Elbow

 

Piping)

Dbl Elbow +

 

 

Dbl Elbow -

 

 

Valve

 

 

Expander

 

 

Reducer

 

 

Norm Entry

 

 

Header Inlet

 

 

Intrusions

 

Anomaly Diams

xxxx (numeric entry)

* Default

 

 

2-19

Page 59
Image 59
Siemens SITRANS FUS1010 NEMA-4X/ IP 65 manual Pipe Configuration Menu Structure