Section 6

1010NFM-3J

 

 

6.4SPECIFICATIONS – CPVC FLOW TUBE

*Typical values, subject to change without notice.

 

Size 1

Size 2

Liquid

Must be compatible with CPVC under

Must be compatible with CPVC under

 

operating conditions and free of sus-

operating conditions and free of sus-

 

pended gasses or solids.

pended gasses or solids.

 

 

 

Pressure Drop

0.28 psi @ 1.5 GPM (5.7 LPM)

0.24 psi @ 4.5 GPM (17.0 LPM)

 

flowing water at 68°F

flowing water at 68°F

 

 

 

Sensitivity

0.0005 GPM (0.002 LPM)

0.0015 GPM (0.0057 LPM)

 

 

 

Linearity

1% of flow for rates above 0.09 GPM

1% of flow for rates above 0.27 GPM

 

(0.34 LPM)

(1.0 LPM)

 

 

 

Repeatability

±0.2% of flow for rates above 0.6 GPM

±0.2% of flow for rates above 1.5 GPM

 

(2.3 LPM)

(5.7 LPM)

 

 

 

Zero Stability

±0.0013 GPM (0.005 LPM)

±0.003 GPM (0.011 LPM)

 

 

 

Accuracy,

±1% of flow over 0.15 GPM (0.57

±1% of flow over 0.5 GPM (1.9 LPM) to

Intrinsic

LPM) to 5 GPM (20 LPM)

25 GPM (95 LPM)

 

 

 

Accuracy, Flow

±0.5% of flow over 0.15 GPM (0.5

±0.5% of flow over 0.5 GPM (1.9 LPM)

Calibrated

LPM) to 5 GPM (20 LPM)

to 25 GPM (95 LPM)

 

 

 

Connection

3/ ” FPT

¾” FPT

 

8

 

6.5SPECIFICATIONS – KYNAR PVDF FLOW TUBE

*Typical values, subject to change without notice.

 

Size 1

Size 2

Liquid

Must be compatible with PVDF

Must be compatible with PVDF under

 

under operating conditions and free

operating conditions and free of

 

of suspended gasses or solids.

suspended gasses or solids.

 

 

 

Pressure Drop

0.28 psi @ 1.5 GPM (5.7 LPM)

0.24 psi @ 4.5 GPM (17.0 LPM)

 

flowing water at 68°F

flowing water at 68°F

 

 

 

Sensitivity

0.0005 GPM (0.002 LPM)

0.0015 GPM (0.006 LPM)

Linearity

1% of flow for rates above 0.09 GPM

1% of flow for rates above 0.27 GPM

 

(0.34 LPM)

(1.0 LPM)

 

 

 

Repeatability

±0.2% of flow for rates above 0.6

±0.2% of flow for rates above 1.5 GPM

 

GPM (2.3 LPM)

(5.7 LPM)

 

 

 

Zero Stability

±0.0013 GPM (0.005 LPM)

±0.003 GPM (0.011 LPM)

 

 

 

Accuracy,

±1% of flow over 0.15 GPM (0.57

±1% of flow over 0.5 GPM (1.9 LPM) to

Intrinsic

LPM) to 5 GPM (20 LPM)

5 GPM (95 LPM)

 

 

 

Accuracy, Flow

±0.5% of flow over 0.15 GPM (0.57

±0.5% of flow over 0.5 GPM (1.9 LPM)

Calibrated

LPM) to 5 GPM (20 LPM)

to 25 GPM (95 LPM)

 

 

 

Connection

3/ ” FPT

3/ ” FPT

 

8

4

6-9