Image 155

set system ip-address 155

 

Usage — You must first set the time zone with the set timezone

 

command for the offset to work properly without the start and end

 

values.

 

Configure summertime before you set the time and date. Otherwise,

 

summertime’s adjustment of the time will make the time incorrect, if the

 

date is within the summertime period.

 

Examples — To enable summertime and set the summertime time zone

 

to PDT (Pacific Daylight Time), type the following command:

 

WX1200# set summertime PDT

 

success: change accepted

 

See Also

 

„ clear summertime on page 115

 

„ clear timezone on page 116

 

„ display summertime on page 130

 

„ display timedate on page 130

 

„ display timezone on page 131

 

„ set timedate on page 156

 

„ set timezone on page 157

 

 

set system

Configures the system IP address. The system IP address determines the

ip-address

interface or source IP address MSS uses for system tasks, including the

 

following:

 

„ Mobility domain operations

 

„ Topology reporting for dual-homed MAP access points

 

„ Default source IP address used in unsolicited communications such as

 

AAA accounting reports and SNMP traps

Syntax set system ip-address ip-addr

„ip-addr— IP address, in dotted decimal notation. The address must be configured on one of the WX switch’s VLANs.

Defaults — None.

Access — Enabled.

Page 155
Image 155
3Com 3CRWX120695A Values, Date is within the summertime period, To PDT Pacific Daylight Time, type the following command